Image distortion correction in fMRI: A quantitative evaluation.

نویسندگان

  • Chloe Hutton
  • Andreas Bork
  • Oliver Josephs
  • Ralf Deichmann
  • John Ashburner
  • Robert Turner
چکیده

A well-recognized problem with the echo-planar imaging (EPI) technique most commonly used for functional magnetic resonance imaging (fMRI) studies is geometric distortion caused by magnetic field inhomogeneity. This makes it difficult to achieve an accurate registration between a functional activation map calculated from an EPI time series and an undistorted, high resolution anatomical image. A correction method based on mapping the spatial distribution of field inhomogeneities can be used to reduce these distortions. This approach is attractive in its simplicity but requires postprocessing to improve the robustness of the acquired field map and reduce any secondary artifacts. Furthermore, the distribution of the internal magnetic field throughout the head is position dependent resulting in an interaction between distortion and head motion. Therefore, a single field map may not be sufficient to correct for the distortions throughout a whole fMRI time series. In this paper we present a quantitative evaluation of image distortion correction for fMRI at 2T. We assess (i) methods for the acquisition and calculation of field maps, (ii) the effect of image distortion correction on the coregistration between anatomical and functional images, and (iii) the interaction between distortion and head motion, assessing the feasibility of using field maps to reduce this effect. We propose that field maps with acceptable noise levels can be generated easily using a dual echo-time EPI sequence and demonstrate the importance of distortion correction for anatomical coregistration, even for small distortions. Using a dual echo-time series to generate a unique field map at each time point, we characterize the interaction between head motion and geometric distortion. However, we suggest that the variance between successively measured field maps introduces additional unwanted variance in the voxel time-series and is therefore not adequate to correct for time-varying distortions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

Effect of Physiological noise on Thoraco-Lumbar spinal cord fMRI in 3T Magnetic field

Introduction: Functional MRI methods have been used to study sensorimotor processing in the brain and the Spinal cord. However, these techniques confront unwanted contributions to the measured signal from physiological fluctuations. For the spinal cord imaging, most of the challenges are consequences of cardiac and respiratory movement artifacts that are considered as signifi...

متن کامل

Assessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements

Introduction:  Image  distortion  is  one  of  the  major  problems  of  magnetic  resonance  imaging  (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is  widely known that the most obvious effect of the inhomogenity of the magnetic fields and the  nonlinearity  of  the  gradient  is  the  Geometric  Distortion  of  MR  tomograms.  In  this  study,  the...

متن کامل

Quantitative Comparison of SPM, FSL, and Brainsuite for Brain MR Image Segmentation

Background: Accurate brain tissue segmentation from magnetic resonance (MR) images is an important step in analysis of cerebral images. There are software packages which are used for brain segmentation. These packages usually contain a set of skull stripping, intensity non-uniformity (bias) correction and segmentation routines. Thus, assessment of the quality of the segmented gray matter (GM), ...

متن کامل

Concurrent Geometric Distortion Correction in Mapping Slice-to-volume (MSV) Motion Correction of fMRI Time Series

D. Yeo, J. A. Fessler, B. Kim Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI, United States, Radiology, University of Michigan Medical School, Ann Arbor, MI, United States Introduction: The accuracy of measuring voxel intensity changes between stimulus and rest images in fMRI echo-planar imaging (EPI) data, from which brain activation maps are computed, is se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 16 1  شماره 

صفحات  -

تاریخ انتشار 2002