Arterial sampler filling time during arterial and venous punctures, and its relationship with mean arterial pressure in human subjects.

نویسندگان

  • Jeffrey J Bender
  • Jennie R Allison
  • Jeremy J Goehring
  • Mihal D Patel
  • Sean M Niederst
  • F Herbert Douce
چکیده

BACKGROUND When obtaining an arterial blood sample via percutaneous puncture, there is a risk of accidentally obtaining venous blood. Conventional methods of confirming arterial blood at the bedside, such as blood color and pulsatile return, can be misleading in patients with low blood pressure or hypoxemia. OBJECTIVE To determine if the arterial sampler filling time can be an accurate indicator of obtaining an arterial blood sample in subjects with various blood pressures. Our hypotheses were that there would be a statistically significant negative correlation between sampler filling time during arterial puncture and mean arterial blood pressure, and a statistically significant difference between venous and arterial filling times in human adults. METHODS Prior to an arterial puncture, we measured and recorded arterial blood pressure noninvasively. During the arterial and venipuncture procedures we measured the amount of time it took to fill the sampler and the volume of blood obtained. A t test for independent samples was calculated to determine if mean arterial sampler filling times were significantly different between the arterial and venous groups. Pearson correlation coefficient was calculated to determine the relationship between mean arterial pressure and seconds of filling time per milliliter in the arterial group. RESULTS This study included 38 human subjects; 22 were adult patients ordered for arterial blood gases by arterial puncture; 16 were normal, healthy, adult volunteers who had a venipuncture performed using an arterial blood sampler. The mean ± SD filling time was 15 ± 4 s/mL for the arterial group and 115 ± 48 s/mL for the venous group, and the difference was significant (P < .001). The range of mean arterial pressures was 69-125 mm Hg; the average mean arterial pressure was 91 ± 13 mm Hg, and the Pearson correlation coefficient for mean arterial pressures and sampler filling times was -0.49 (P = .02). CONCLUSION Our results were consistent with a laboratory study showing a significant difference between arterial and venous filling times and a negative correlation between mean arterial pressure and sampler filling time, but our times in adult subjects were longer. Respiratory therapists may find arterial sampler filling time as a useful indicator of successful arterial puncture at the bedside.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of abnormal blood pressure on arterial sampler filling times.

BACKGROUND Sampler filling time begins with the initial flash of blood in the needle hub until the preset sampler volume is obtained. Previous studies have shown statistically significant differences between arterial and venous sampler filling times, but included only a few subjects with abnormal blood pressures. OBJECTIVE To determine whether the time required to fill a vented arterial sampl...

متن کامل

Effects of mean arterial pressure and needle size on arterial sampler filling time.

BACKGROUND Arterial blood sampling is subject to numerous pre-analytical errors, one of which is inadvertent venous blood sampling. Especially when assessing oxygenation and titrating ventilation, accidental venous blood sampling may lead to inappropriate respiratory care and repeated percutaneous punctures. OBJECTIVE To determine the effects of mean systemic blood pressure and needle size on...

متن کامل

Comparison of sampler filling times among selected arterial blood samplers.

BACKGROUND True arterial blood samples are essential in making clinical decisions for respiratory patients. Previous studies using only the Portex Pro-Vent arterial sampler have shown a significant difference between arterial and venous filling times. The goal of this study was to determine whether there is a statistically significant difference between sampler filling times measured at a norma...

متن کامل

تخمین فشار متوسط شریانی توسط پایش تهاجمی فشار شریانی با مانومتر

Background: Direct monitoring of arterial pressure using a transducer system is not affordable in most operating rooms and ICU wards in Iran. It is, however, possible to use an aneroid manometer instead, but it is not standardized yet, nor studied enough and its measurements may not be interpretable. Methods: To study the correlation of the arterial pressure readings between a manometer and a ...

متن کامل

Predicting factors of serum lactate in patients under general anesthesia with propofol during spine surgery

Introduction: Increased serum lactate is seen during surgery due to tissue hypoxia. There have been reports of propofol infusion syndrome due to long-term use of this drug, especially in intensive care patients. This study was conducted to evaluate the factors affecting serum lactate levels in patients under general anesthesia with propofol in spine surgery. Methods: In a cross-sectional study...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 57 11  شماره 

صفحات  -

تاریخ انتشار 2012