Mouse heart valve structure and function: echocardiographic and morphometric analyses from the fetus through the aged adult.

نویسندگان

  • Robert B Hinton
  • Christina M Alfieri
  • Sandra A Witt
  • Betty J Glascock
  • Philip R Khoury
  • D Woodrow Benson
  • Katherine E Yutzey
چکیده

The purpose of this study is to provide standard echocardiographic and morphometric data for normal mouse valve structure and function from late fetal to aged adult stages. Cross-sectional, two-dimensional and Doppler transthoracic echocardiography was performed in C57BL6 mice anesthetized with 1% to 2% isoflurane at embryonic day 18.5 (late fetal), 10 days (neonate), 1 mo (juvenile), 2 mo (young adult), 9 mo (old adult), and 16 mo (aged adult). Normal annulus dimensions indexed to age or weight, and selected flow velocities, were established by echocardiography. After echocardiographic imaging, hearts were harvested and histological and morphometric analyses were performed. Morphometric analysis demonstrated a progressive valve thinning and elongation during the fetal and juvenile stages that plateaued during adult stages (ANOVA, P < 0.01); however, there was increased thickening of the hinge of the aortic valve with advanced age, reminiscent of human aortic valve sclerosis. There was no age-related calcification. The results of this study provide comprehensive echocardiographic and morphometric data for normal mouse valve structure and function from late fetal to aged adult stages and should prove useful as a reference standard for future studies using mouse models of progressive valve disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure

  Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...

متن کامل

بررسی بالینی و اکوکاردیوگرافیک تنگی دریچه میترال در بیماران مراجعه کننده به بیمارستان های امام خمینی و امیراعلم1

Rheumatic heart disease is a serious health problem in developing countries. The present study was conducted to evaluate clinical and echocardiographic findings of Mitral stenosis and their relationship with patients functional classes. We studied records of 400 patients with symptomatic mitral stenosis (71% female, mostly in 20s or 30s and 54% function class II) treated in two hospitals in Teh...

متن کامل

Severe Persistant Cyanosis in a Newborn Due to Prominent Eustachian Valve

ABSTRACTThe valves of right horn of systemic venous sinus are prominent structures within the right atrium during early embryonic period. Involution of these structures may not be complete, resulting in a spectrum of anatomical presentations such as cyanosis. A full-term male neonate referred to our hospital for precise evaluation of severe cyanosis on the first day of life. Echocardiographic e...

متن کامل

Correlation between echocardiographic and morphological investigations of lesions of the tricuspid valve diagnosed during fetal life.

OBJECTIVE To assess the degree of agreement between the fetal echocardiographic and postmortem examination of hearts from fetuses with severe malformations of the tricuspid valve. DESIGN A retrospective study to analyse echocardiographic recordings and make comparisons with postmortem findings. SETTING Tertiary referral centre for fetal echocardiography. Institute for cardiac morphology. ...

متن کامل

Doppler echocardiographic findings in tissue engineered aortic valve in a sheep model

Background: Heart valve diseases are considered a common disease in human and animals, and valve replacement is an option for treatment of valvular diseases. Objectives: In this study efficacy of a tissue engineered valve in thoracic aorta was evaluated with transthoracic echocardiography. Methods: This study was undertaken on 6 male sheep. Echocardiography was performed on all sheep 24 hours b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 294 6  شماره 

صفحات  -

تاریخ انتشار 2008