Detection of Carbapenemases in Clinical Enterobacteriaceae Isolates Using the VITEK AST-N202 Card

نویسندگان

  • Il Kwon Bae
  • Hyun-Kyung Kang
  • In-Ho Jang
  • Woonhyoung Lee
  • Keonhan Kim
  • Jung Ok Kim
  • Seok Hoon Jeong
  • Kyungwon Lee
چکیده

BACKGROUND The rapid and accurate detection of carbapenemase-producing Enterobacteriaceae (CPE) in clinical microbiology laboratories is essential for the treatment and control of infections caused by these microorganisms. This study was performed to evaluate the ability of the VITEK AST-N202 card to detect CPE isolates. MATERIALS AND METHODS A total of 43 (Klebsiella pneumoniae, n = 37; Escherichia coli, n = 3; and Enterobacter cloacae, n = 3) CPE isolates and 79 carbapenemase-non-producing Enterobacteriaceae (CNE) isolates were included in this study. The CPE isolates harbored KPC-2 (n = 11), KPC-3 (n = 20), GES-5 (n = 5), VIM-2 (n = 2), IMP-1 (n = 1), NDM-1 (n = 2), or OXA-232 (n = 2). Of the 79 CNE isolates, eight K. pneumoniae isolates were resistant to ertapenem, imipenem, and meropenem, while the remaining 71 isolates were susceptible to the carbapenems. Antimicrobial susceptibilities were tested using the VITEK AST-N202 card, and the results were interpreted as positive when the isolates showed resistant or intermediate results. Modified-Hodge tests (MHTs) were performed using ertapenem or meropenem disks for the screening of carbapenemase production. Polymerase chain reaction (PCR) and direct sequencing were used to identify β-lactamase genes. RESULTS Sensitivity of MHT with ertapenem and meropenem disks for the detection of carbapenemase was 81.4% (35/43) and 81.4% (35/43), respectively, and a combination with both antibiotic disks increased the sensitivity to 88.4% (38/43). Specificity of the MHT was 100% (79/79) for the CNE isolates. Sensitivity of ertapenem, imipenem, and meropenem as assessed by the VITEK AST-N202 card was 100% (43/43), 93% (40/43), and 95.3% (41/43), respectively. Specificity (89.8%, 71/79) of the test with each carbapenem was improved to 100% (71/71) when eight carbapenem-resistant CNE isolates were excluded from the testing. CONCLUSION The VITEK AST-N202 card showed high sensitivity for the detection of carbapenemases in Enterobacteriaceae strains. PCR and sequencing experiments for the detection of carbapenemases are recommended when clinical Enterobacteriaceae isolates show non-susceptibility to carbapenems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the VITEK 2 AST N-054 test card for the detection of extended-spectrum beta-lactamase production in Escherichia coli with CTX-M phenotypes.

OBJECTIVES A new VITEK 2 antibiotic susceptibility testing (AST) card, AST N-054, was introduced for aerobic gram-negative bacilli in 2007 and has been widely adopted for routine use in the UK. We evaluated its performance for detecting extended-spectrum beta-lactamase (ESBL) production in Escherichia coli. METHODS ESBL-producing faecal isolates of E. coli (n = 137) from residents in nursing ...

متن کامل

Performance of MicroScan WalkAway and Vitek 2 for detection of oxacillin resistance in a set of methicillin-resistant Staphylococcus aureus isolates with diverse genetic backgrounds.

Of 104 genotypically diverse methicillin-resistant Staphylococcus aureus (MRSA) isolates tested with the MicroScan WalkAway (Pos MIC 24 panel) and Vitek 2 (AST-P549 card) systems, 7 and 6 isolates, respectively, showed an oxacillin MIC of < or =2mg/liter. Most of these MRSA isolates were community acquired. However, if the cefoxitin screen of AST-P549 was also considered, MRSA detection failed ...

متن کامل

Evaluation of new Vitek 2 card and disk diffusion method for determining susceptibility of Staphylococcus aureus to oxacillin.

Detection of methicillin resistance in Staphylococcus aureus is a challenge, especially low-level resistance, which is often misdiagnosed. The aim of this study was to compare the diagnostic accuracies of the automated Vitek 2 system and disk diffusion tests, using cefoxitin and moxalactam, for the detection of methicillin resistance in S. aureus strains. Four sets of genotypically diverse isol...

متن کامل

Evaluation of the Vitek GPS-TA card for laboratory detection of high-level gentamicin and streptomycin resistance in enterococci.

The Vitek GPS-TA card (Vitek Systems, Hazelwood, Mo.) was compared with single-concentration broth microdilution and disk diffusion methods using high-content disks for the detection of high-level resistance to gentamicin and streptomycin in 99 isolates of enterococci (81 Enterococcus faecalis isolates and 18 Enterococcus faecium isolates). The GPS-TA card accurately detected high-level resista...

متن کامل

Rapid antibiotic sensitivity testing and trimethoprim-mediated filamentation of clinical isolates of the Enterobacteriaceae assayed on a novel porous culture support.

A porous inorganic material (Anopore) was employed as a microbial culture and microcolony imaging support. Rapid Anopore-based antibiotic sensitivity testing (AST) methods were developed to assess the growth of clinical isolates, with the primary focus on testing the response of the Enterobacteriaceae to trimethoprim, but with the method supporting a wider applicability in terms of strains and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 47  شماره 

صفحات  -

تاریخ انتشار 2015