Neck Muscle EMG-Force Relationship and Its Reliability During Isometric Contractions

نویسندگان

  • Riccardo Lo Martire
  • Kristofer Gladh
  • Anton Westman
  • Björn O. Äng
چکیده

BACKGROUND Susceptible to injury, the neck is subject to scientific investigations, frequently aiming to elucidate possible injury mechanisms via surface electromyography (EMG) by indirectly estimating cervical loads. Accurate estimation requires that the EMG-force relationship is known and that its measurement error is quantified. Hence, this study examined the relationship between EMG and isometric force amplitude of the anterior neck (AN), the upper posterior neck (UPN), and the lower posterior neck (LPN) and then assessed the relationships' test-retest reliability across force-percentiles within and between days. METHODS EMG and force data were sampled from 18 participants conducting randomly ordered muscle contractions at 5-90% of maximal voluntary force during three trials over 2 days. EMG-force relationships were modeled with general linear mixed-effects regression. Overall fitted lines' between-trial discrepancies were evaluated. Finally, the reliability of participants' fitted regression lines was quantified by an intraclass correlation coefficient (ICC) and the standard error of measurement (SEM). RESULTS A rectilinear model had the best fit for AN while positively oriented quadratic models had the best fit for UPN and LPN, with mean adjusted conditional coefficients of determination and root mean square errors of 0.97-0.98 and 4-5%, respectively. Overall EMG-force relationships displayed a maximum 6% between-trial discrepancy and over 20% of maximal force, and mean ICC was above 0.79 within day and 0.27-0.61 between days across areas. Corresponding SEM was below 12% both within and between days across areas, excluding UPN between days, for which SEM was higher. CONCLUSIONS EMG-force relationships were elucidated for three neck areas, and provided models allow inferences to be drawn from EMG to force on a group level. Reliability of EMG-force relationship models was higher within than between days, but typically acceptable for all but the lowest contraction intensities, and enables adjustment for measurement imprecision in future studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of normalisation methods for EMG analysis of neck muscles.

Acceptable reliability of normalisation contractions in electromyography (EMG) is paramount for testing conducted over a number of days or if normal laboratory strength testing equipment is unavailable. This study examined the reliability of maximal voluntary isometric contractions (MVIC) and sub-maximal (60%) isometric contractions for use in neck muscle EMG studies. Surface EMG was recorded b...

متن کامل

Neural control of superficial and deep neck muscles in humans Abbreviated title: Neural control of neck muscles

Human neck muscles have a complex multi-layered architecture. The role and neural control of these neck muscles were examined in nine seated subjects performing three series of isometric neck muscle contractions: i) 50 N contractions in eight fixed horizontal directions, ii) 25 N contractions and iii) 50 N contractions, both with a continuously changing horizontal force direction. Activity in t...

متن کامل

Neural control of superficial and deep neck muscles in humans.

Human neck muscles have a complex multi-layered architecture. The role and neural control of these neck muscles were examined in nine seated subjects performing three series of isometric neck muscle contractions: 50-N contractions in eight fixed horizontal directions, 25-N contractions, and 50-N contractions, both with a continuously changing horizontal force direction. Activity in the left ste...

متن کامل

Force depression in human quadriceps femoris following voluntary shortening contractions.

The purpose of this study was to investigate whether the isometric muscle force, redeveloped following maximal-effort voluntary shortening contractions in human skeletal muscle, is smaller than the purely isometric muscle force at the corresponding length. Isometric knee extensor moments, surface electromyographic (EMG) signals of quadriceps femoris, and interpolated twitch moments (ITMs) were ...

متن کامل

The relationship between electromyogram and muscle force.

Some guidelines are given for the interpretation of the electromyogram (EMG). In static isometric contractions there is, usually a linear, relationship between muscle force and smoothed rectified EMG (SRE). It should be considered, however, that most of the time several muscles are active simultaneously around a joint. This finding implies that the relationship between the SRE of a single muscl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2017