Can clinically relevant dose errors in patient anatomy be detected by gamma passing rate or modulation complexity score in volumetric-modulated arc therapy for intracranial tumors?

نویسندگان

  • Shingo Ohira
  • Yoshihiro Ueda
  • Masaru Isono
  • Akira Masaoka
  • Misaki Hashimoto
  • Masayoshi Miyazaki
  • Masaaki Takashina
  • Masahiko Koizumi
  • Teruki Teshima
چکیده

We investigated whether methods conventionally used to evaluate patient-specific QA in volumetric-modulated arc therapy (VMAT) for intracranial tumors detect clinically relevant dosimetric errors. VMAT plans with coplanar arcs were designed for 37 intracranial tumors. Dosimetric accuracy was validated by using a 3D array detector. Dose deviations between the measured and planned doses were evaluated by gamma analysis. In addition, modulation complexity score for VMAT (MCSv) for each plan was calculated. Three-dimensional dose distributions in patient anatomy were reconstructed using 3DVH software, and clinical deviations in dosimetric parameters between the 3DVH doses and planned doses were calculated. The gamma passing rate (GPR)/MCSv and the clinical dose deviation were evaluated using Pearson's correlation coefficient. Significant correlation (P < 0.05) between the clinical dose deviation and GPR was observed with both the 3%/3 mm and 2%/2 mm criteria in clinical target volume (D99), brain (D2), brainstem (D2) and chiasm (D2), albeit that the correlations were not 'strong' (0.38 < |r| < 0.54). The maximum dose deviations of brainstem were up to 4.9 Gy and 2.9 Gy for Dmax and D%, respectively in the case of high GPR (98.2% with 3%/3 mm criteria). Regarding MCSv, none of the evaluated organs showed a significant correlation with clinical dose deviation, and correlations were 'weak' or absent (0.01 < |r| < 0.21). The use of high GPR and MCSv values does not always detect dosimetric errors in a patient. Therefore, in-depth analysis with the DVH for patient-specific QA is considered to be preferable for guaranteeing safe dose delivery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Investigation of error detection capabilities of phantom, EPID and MLC log file based IMRT QA methods

A patient specific quality assurance (QA) should detect errors that originate anywhere in the treatment planning process. However, the increasing complexity of treatment plans has increased the need for improvements in the accuracy of the patient specific pretreatment verification process. This has led to the utilization of higher resolution QA methods such as the electronic portal imaging devi...

متن کامل

Purpose: to validate the clinical effectiveness of Control Point Analysis (CPA) software and establish a comprehensive quality assurance (QA) program for Volumetric Modulated Arc Therapy (VMAT) treatment. Methods: The comparison and gamma analysis of ArcCHECKâ„¢ measurement and treatment planning

ID: 19178 Title: Establishing Comprehensive Quality Assurance Program for Volumetric Modulated Arc Therapy -Clinical Study Using Control Point Analysis Software Purpose: to validate the clinical effectiveness of Control Point Analysis (CPA) software and establish a comprehensive quality assurance (QA) program for Volumetric Modulated Arc Therapy (VMAT) treatment. Methods: The comparison and gam...

متن کامل

Purpose: to validate the clinical effectiveness of Control Point Analysis (CPA) software and establish a comprehensive quality assurance (QA) program for Volumetric Modulated Arc Therapy (VMAT) treatment. Methods: The comparison and gamma analysis of ArcCHECKTM measurement and treatment planning

ID: 19178 Title: Establishing Comprehensive Quality Assurance Program for Volumetric Modulated Arc Therapy -Clinical Study Using Control Point Analysis Software Purpose: to validate the clinical effectiveness of Control Point Analysis (CPA) software and establish a comprehensive quality assurance (QA) program for Volumetric Modulated Arc Therapy (VMAT) treatment. Methods: The comparison and gam...

متن کامل

A study on the correlation between plan complexity and gamma index analysis in patient specific quality assurance of volumetric modulated arc therapy.

AIM To evaluate the new Octavius 4D system for patient specific quality assurance and to study the correlation between plan complexity and gamma index analysis in patient specific quality assurance of VMAT using the Octavius 4D system. BACKGROUND McNiven (2010) proposed a study to evaluate the utility of a complexity metric, the Modulation Complexity Score, to evaluate the relationship of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 58  شماره 

صفحات  -

تاریخ انتشار 2017