Diagnosis of peripheral pulmonary lesions with radial probe endobronchial ultrasound-guided bronchoscopy.

نویسندگان

  • Viboon Boonsarngsuk
  • Wasana Kanoksil
  • Sarangrat Laungdamerongchai
چکیده

INTRODUCTION The diagnosis of peripheral pulmonary lesions (PPLs) is a challenging task for pulmonologists. Radial probe endobronchial ultrasound (R-EBUS) has been developed to enhance diagnostic yield. The objective of this study was to evaluate the effectiveness of R-EBUS in the diagnosis of PPLs. METHODS A retrospective study was conducted on 174 patients diagnosed with PPLs who underwent EBUS-guided bronchoscopy. Histological examination of specimens obtained by transbronchial lung biopsy (TBLB) and cytological examinations of brushing smear, brush rinse fluid and bronchoalveolar lavage fluid (BALF) were evaluated for the diagnosis. RESULTS The mean diameter of the PPLs was 25.1 ± 10.7 mm. The final diagnoses included 129 malignancies and 45 benign lesions. The overall diagnostic yield of EBUS-guided bronchoscopy was 79.9%. Neither size nor etiology of the PPLs influenced the diagnostic performance of EBUS-guided bronchoscopy (82.9% vs. 74.6% for PPLs>20mm and PPLs≤20mm; p=0.19, and 82.9% vs. 71.1% for malignancy and benign diseases; p=0.09). TBLB rendered the highest yield among these specimens (69.0%, 50.6%, 42.0%, and 44.3% for TBLB, brushing smear, brush rinse fluid, and BALF, respectively; p<0.001). The combination of TBLB, brush smear, and BALF provided the greatest diagnostic yield, while brush rinse fluid did not add benefits to the outcomes. CONCLUSION R-EBUS-guided bronchoscopy is a useful technique in the diagnosis of PPLs. To achieve the highest diagnostic performance, TBLB, brushing smear and bronchoalveolar lavage should be performed together.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions: Initial Experience in an Indian Tertiary Healthcare Centre

Introduction : Diagnosis of peripheral pulmonary nodules is confusing; therefore, an accurate and safe lung biopsy can prevent unnecessary invasive diagnostic procedures. This study soughtto study the diagnostic yield, sensitivity, specificity, and negative and positive predictive values (NPV and PPV) of radial probe endobronchial ultrasound (EBUS)-guided biopsy for peripheral pulmonary lesions...

متن کامل

Radial endobronchial ultrasound in diagnosing peripheral lung lesions in a high tuberculosis setting

BACKGROUND Current data for the utility of radial endobronchial ultrasound (EBUS) in investigating peripheral lung lesions (PLLs) has been restricted to populations with low pulmonary tuberculosis (TB) incidence. The aim of this study was to assess the diagnostic utility of radial EBUS with guide sheath in the diagnosis of peripheral lung lesions in Singapore, a high TB incidence setting. MET...

متن کامل

Fluoroscopic-Guided Radial Endobronchial Ultrasound Without Guide Sheath For Peripheral Pulmonary Lesions: A Safe And Efficient Combination.

BACKGROUND Several guidelines recommend computed tomography scans for populations with high-risk for lung cancer. The number of individuals evaluated for peripheral pulmonary lesions (PPL) will probably increase, and with it non-surgical biopsies. Associating a guidance method with a target confirmation technique has been shown to achieve the highest diagnostic yield, but the utility of broncho...

متن کامل

Endobronchial ultrasound for the diagnosis of peripheral pulmonary lesions. A controlled study with fluoroscopy.

INTRODUCTION Fluoroscopy-guided bronchoscopy is usually performed for the diagnosis of peripheral pulmonary lesions (PPL), but the diagnostic yield varies widely among studies. Endobronchial ultrasound (EBUS) can increase the diagnostic yield of bronchoscopic diagnosis of PPL. OBJECTIVE To compare the diagnostic yield of fluoroscopy-guided bronchoscopy and EBUS with fluoroscopy-guided broncho...

متن کامل

A new middle-range diameter bronchoscope with large channel for transbronchial sampling of peripheral pulmonary lesions.

OBJECTIVE Although the diagnostic yield of guided bronchoscopy for peripheral pulmonary lesions has improved to 70%, it is still low compared with transthoracic needle aspiration. We produced a new bronchoscope with middle-range diameter and large channel (BF-Y0053, Olympus, Japan), and evaluated its diagnostic efficacy for peripheral pulmonary lesions. METHODS This was a retrospective study ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archivos de bronconeumologia

دوره 50 9  شماره 

صفحات  -

تاریخ انتشار 2014