Exergy Analysis of a Parallel-Plate Active Magnetic Regenerator with Nanofluids
نویسندگان
چکیده
This paper analyzes the energetic and exergy performance of an active magnetic regenerative refrigerator using water-based Al2O3 nanofluids as heat transfer fluids. A 1D numerical model has been extensively used to quantify the exergy performance of a system composed of a parallel-plate regenerator, magnetic source, pump, heat exchangers and control valves. Al2O3-water based nanofluids are tested thanks to CoolProp library, accounting for temperature-dependent properties, and appropriate correlations. The results are discussed in terms of the coefficient of performance, the exergy efficiency, and the cooling power as a function of the nanoparticle volume fraction and blowing time for a given geometrical configuration. It is shown that while the heat transfer between the fluid and solid is enhanced, it is accompanied by smaller temperature gradients within the fluid and larger pressure drops when increasing the nanoparticle concentration. It leads in all configurations to lower performance compared to the base case with pure liquid water.
منابع مشابه
The Exergy Optimization of a Flat-Plate Solar Collector Using AL2O3-Water, CuO-Water and TiO2-Water Nanofluids by Genetic Algorithm
In this study, the exergy efficiency of a flat plate solar collector using Al2O3, TiO2, CuO nanoparticles and pure water as base fluid is studied. Solar radiation is selected between 200 to 600 W/m2. The method to determine optimum values of optimization variables has been developed by Genetic Algorithm Toolbox in MATLAB software. Results show by increasing solar radiation the optimized exergy ...
متن کاملExperimental Analysis of Heat Transfer and Friction Factor in Plate Heat Exchanger with Different Orientations Using Al2O3 Nanofluids
Experimental investigations has been done to find out the heat transfer characteristics and friction factor of water based Al2O3 nanofluids as a coolant in brazed plate heat exchanger. Plate heat exchanger either use horizontally or vertically. The base plate of the plate heat exchanger was kept inclined at (0⁰, 30⁰ ,60⁰, 90⁰). The experimentation have been done on the two different concentrat...
متن کاملAdvanced Exergy Analysis for a Solar Double Stage Absorption Chiller
.............................................................................................................................. i List of Figures ................................................................................................................... vi List of Tables .................................................................................................................... i...
متن کاملImpact of Magnetic Field on Convective Flow of a Micropolar Fluid with two Parallel Heat Source
A numerical study is performed to analysis the buoyancy convection induced by the parallel heated baffles in an inclined square cavity. The two side walls of the cavity are maintained at a constant temperature. A uniformly thin heated plate is placed at the centre of the cavity. The horizontal top and bottom walls are adiabatic. Numerical solutions of governing equations are obtained using the ...
متن کاملThermo-Exergy Optimization of Gas Turbine Cycle with Two Different Regenerator Designs
Abstract—A thermo-exergy optimization of a gas turbine cycle with two different regenerator designs is established. A comparison was made between the performance of the two regenerators and their roles in improving the cycle efficiencies. The effect of operational parameters (the pressure ratio of the compressor, the ambient temperature, excess of air, geometric parameters of the regenerators, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Entropy
دوره 19 شماره
صفحات -
تاریخ انتشار 2017