Development of KSTAR ECE imaging system for measurement of temperature fluctuations and edge density fluctuations.

نویسندگان

  • G S Yun
  • W Lee
  • M J Choi
  • J B Kim
  • H K Park
  • C W Domier
  • B Tobias
  • T Liang
  • X Kong
  • N C Luhmann
  • A J H Donné
چکیده

The ECE imaging (ECEI) diagnostic tested on the TEXTOR tokamak revealed the sawtooth reconnection physics in unprecedented detail, including the first observation of high-field-side crash and collective heat transport [H. K. Park, N. C. Luhmann, Jr., A. J. H. Donné et al., Phys. Rev. Lett. 96, 195003 (2006)]. An improved ECEI system capable of visualizing both high- and low-field sides simultaneously with considerably better spatial coverage has been developed for the KSTAR tokamak in order to capture the full picture of core MHD dynamics. Direct 2D imaging of other MHD phenomena such as tearing modes, edge localized modes, and even Alfvén eigenmodes is expected to be feasible. Use of ECE images of the optically thin edge region to recover 2D electron density changes during L/H mode transitions is also envisioned, providing powerful information about the underlying physics. The influence of density fluctuations on optically thin ECE is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relatively scaled ECE temperature profiles of KSTAR plasmas.

A scheme to obtain relatively scaled profiles of electron cyclotron emission (ECE) temperature directly from uncalibrated raw radiometer data is proposed and has been tested for the 2009 campaign KSTAR plasmas. The proposed method utilizes a position controlled system to move the plasma adiabatically and compares ECE radiometer channels at the same relative radial positions assuming the profile...

متن کامل

Beam Emission Spectroscopy Measurements on KSTAR

Beam emission spectroscopy measures electron density from the Doppler-shifted light emission of a heating beam excited by beam-plasma particle collisions [1]. From the measured light intensity one can calculate the electron density after proper calibration. If sufficient light is available, this technique enables us the study of electron density fluctuations and their spatial distribution via t...

متن کامل

Density Fluctuations of Two Major Aspergillus Species Airborne Spores in Pistachio Growing Regions of Iran

Contamination of pistachio nuts by aflatoxigenic strains of Aspergillus species is the greatest constraint to production and export of pistachio nuts in Iran, the leading producer of pistachio nuts in the world. Kerman province is the main region in Iran where 85%, of pistachio nuts are produced. Determining the population density of Aspergillus spores in the orchards and terminals which are th...

متن کامل

PSFC / JA - 97 - 23 ELMs and Fast Edge Fluctuations in Alcator C - Mod

Just above the H-mode threshold power at low density, small amplitude high repetition rate (1 5 kHz) Type III Edge Localized Modes (ELMs) are observed. At higher input power, the H-modes become ELM-free. At high density and high input power (Ie > 2.2 x 1020 m3, P," > 2 MW), the plasma often enters a new H-mode regime now called the Enhanced D, H-mode, which is a steady-state Hmode often without...

متن کامل

Synergy of multiviewing spectroscopic diagnostics on COMPASS-D (invited)

Related Articles Development of multi-channel Doppler spectroscopic measurement system using 8 × 8 multianode photomultiplier tube assembly Rev. Sci. Instrum. 83, 083103 (2012) Electron density and temperature profile diagnostics for C-2 field reversed configuration plasmas Rev. Sci. Instrum. 83, 10E339 (2012) Analysis of edge density fluctuation measured by trial KSTAR beam emission spectrosco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 81 10  شماره 

صفحات  -

تاریخ انتشار 2010