An Ultrasonic Imaging Speckle Supression and Contrast Enhancement Technique by Means of Frequency Compounding and Coded Excitation

نویسندگان

  • Jose R. Sanchez
  • Michael L. Oelze
چکیده

A method for improving the contrast resolution of B-mode images is proposed by combining the speckle reduction technique of frequency compounding (FC), and the coded excitation and pulse compression technique called resolution enhancement compression (REC). FC suppresses speckle but at the expense of a reduction in axial resolution. Using REC the axial resolution and bandwidth of the imaging system was doubled. Therefore, by combining REC with FC (RECFC), the trade-off between axial resolution and contrast enhancement was extended significantly. Simulations and experimental measurements were conducted with a singleelement transducer (f/2.66) having a center frequency of 2.25 MHz and a -3-dB bandwidth of 50%. Simulations and measurements of hyperechoic (+6dB) tissue-mimicking targets were imaged. Two FC cases were evaluated: full-, and half-width of the true impulse response bandwidth. The image quality metrics used to compare REC-FC to conventional pulsing (CP) and CP-FC were: contrast-tonoise ratio (CNR), speckle signal-to-noise ratio and histogram percent overlap. Increases in CNR of 121%, and 230% were obtained in experiments when comparing REC-FC for the full-, and half-width cases to CP. Improved lesion detectability was observed by using RECFC. Coded excitation; pulse compression; contrast; frequency compounding; frequency diversity; speckle

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resolution Enhancement and Frequency Compounding Techniques in Ultrasound . Proposal Type : Innovative Student

Ultrasound non destructive evaluation uses high frequency ultrasound to interrogate materials without affecting their performance or structure. The overreaching goal of this project is to effectively characterize and image Biofilms that are known to cause infections in the middle ear epithelial surfaces in children. The quality of B-scan images generated is primarily governed by the axial resol...

متن کامل

Optimization of Axial Resolution in Ultrasound Elastography

To improve the axial resolution of ultrasonic elastography, by taking the advantage of code excitation and frequency compounding, multi-frequency with coded excitation for elastography (FCCE) was proposed. FCCE adopts the Chirp signal excitation scheme and strikes a balance in the selection of sub-signal bandwidth, the bandwidth overlap and the number of sub-strain image based on theoretical de...

متن کامل

Frequency Smoothed Robust Capon Beamformer Applied to Medical Ultrasound Imaging

Recently, adaptive array beamforming has been applied to medical ultrasound imaging and achieved promising performance improvement. However, the current robust Capon beamformer with spatial smoothing (RCB-SS) is implemented in the time domain, which does not fully utilise the large bandwidth of ultrasound signals and spatial smoothing reduces the effective aperture. In this dissertation, we pro...

متن کامل

Spatial compounding in 3D imaging of limbs.

Effects of spatial compounding on image resolution and speckle noise are studied. Using computer simulation, it is shown that spatial compounding using averaged reconstruction can significantly improve lateral resolution while slightly deteriorate axial resolution. The amount of net resolution improvement depends mainly on the compound angle, but is insensitive to the number of component images...

متن کامل

Stochastic explanation of speckle contrast detection in ultrasound-modulated optical tomography.

Ultrasound-modulated optical tomography is an imaging technique that detects ultrasonically tagged light in optically turbid media to obtain images with optical contrast and ultrasonic spatial resolution. A CCD-camera-based speckle contrast detection scheme has been introduced previously to detect modulated light emerging from the ultrasonic sample volume. Differences in speckle contrast were e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007