[Anterior '3-in-1' blockade: partial, total or overdimensioned block? Correlation between anatomy, clinic and radio images.].
نویسنده
چکیده
BACKGROUND AND OBJECTIVES Classic anterior 3-in-1 blockade has been questioned as to the anesthetic involvement of its three participant nerves: femoral, lateral cutaneous of thigh and obturator. This study aimed at evaluating the outcome of anterior 3-in-1 blockade through: single injection (G1), short catheters (G2) and long catheters (G3). 3-in-1 blockades identified as total or overdimensioned were additionally investigated by radio images. METHODS The identification of iliac subfascial space in 3-in-1 blockades with single injection or catheters has been made by loss of resistance to air. In several painful events, anesthetic volume has varied 30 to 40 mL and cranial catheters introduction was up to 18 cm in the iliac subfascial space. When clinical research would point to the involvement of the obturator nerve or other nerve additional to 3-in-1 blockade, investigation was complemented by radiographic or TC-Scan studies aiming at establishing correspondence with pelvic anatomy. RESULTS The involvement of lateral cutaneous of thigh and obturator nerves has not been constant, as opposed to the femoral nerve. No total 3-in-1 blockade with single injection (G1) was observed in our study, but rather 2-in-1, with eventual participation of the femoral branch of the genitofemoral nerve (2.5-in-1 blockade). However, when short catheters were used (G2), there has been 3-in-1 blockade in just one patient, while with long catheters (G3) introduced in the cephalad direction until 18 cm in the iliac subfascial space, three overdimensioned 3-in-1 blockades were recorded, with the additional involvement of common fibular nerve in two patients and tibial nerve in one patient. CONCLUSIONS In spite of the small sample size, single injection (G1) has always provided 2-in-1 or 2.5-in-1 blockade without the participation of the obturator nerve. With short catheters (G2) 3-in-1 blockade was classified as total in 6.6% of cases (one patient). With long catheters (G3), however, results seem to be more predictable as compared to the other groups, especially when the catheter reaches the lumbosacral paravertebral space, resulting in total 3-in-1 blockade in 20% of cases (3 patients) or more uncommonly, in overdimensioned 3-in-1 blockade in 13.2% of cases (2 patients).
منابع مشابه
بررسی شدت نسبی سیگنال تصاویر Magnetic Resonance در بافت رترودیسکال و عضله پتریگوئید خارجی و رابطه آن با یافتههای Magnetic Resonance Imaging
Background and Aims: Disc displacement is the most common temporomandibular joint disorder and magnetic resonance imaging (MRI) is the gold standard in its diagnosis. This disorder can lead to changes in signal intensity of magnetic resonance (MR). The purpose of this study was evaluation of correlation between relative signal intensity of MR images of retrodiscal tissue, superior and inferior ...
متن کاملبررسی میزان بزرگنمایی عمودی رادیوگرافی پانورامیک در مقایسه با CBCT به تفکیک محل آناتومیک
Background: Currently, dental implant is one of the most modern approaches to teeth replacement. Panoramic radiography is considered as the prerequisite for implant therapy. The purpose of the present study was to investigate the vertical magnification of digital panoramic images in various anatomic parts of the mandible. Method: A total of 30 patients referred to Sajjad Radiography Center for...
متن کاملبررسی ارتباط وقوع بلوک دهلیزی- بطنی با الکتروکاردیوگرام اولیه بیماران سکته حاد تحتانی
Background and Aim: Presence of ischemic changes on the anterior surface of heart and AV block worsen the prognosis of acute Inferior Mycocardial Infarction (MI). The rate of mortality increases with the occurrence of AV block in inferior MI.The aim of this study was to predict and diagnose acute Inferior MI in patients with AV block based on ECG and clinical features.Patients and Methods: ...
متن کاملMeasurement of Left Ventricular Myocardium Wall Instantaneous Motions with Echocardiographic Sequence Images
Background & Aims: One of the important aims of quantitative cardiac image processing is the clarification of myocardial motions in order to derive biomechanical behavior of the heart in the disease condition. In this study we presented a computerized analysis method for detecting the instantaneous myocardial changes by using 2D echocardiography images. Methods: The analysis was performed on th...
متن کاملThe Anterior Interosseus Artery Perforator Flap: Anatomical Dissections and Clinical Study
BACKGROUND Reconstruction of upper extremity deformities continues to be a challenge to the reconstructive surgeon. Various loco regional, distant and free flaps are available for reconstruction. However, each has its own set of advantages and disadvantages. Of the commonly performed local flaps, radial artery forearm flap, and the posterior interosseus artery flap stand out prominently. Rec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista brasileira de anestesiologia
دوره 54 4 شماره
صفحات -
تاریخ انتشار 2004