In-vitro performance of the Enlite Sensor in various glucose concentrations during hypobaric and hyperbaric conditions.

نویسندگان

  • Peter Adolfsson
  • Hans Ornhagen
  • Bengt M Eriksson
  • Raghavendhar Gautham
  • Johan Jendle
چکیده

BACKGROUND There is a need for reliable methods of glucose measurement in different environmental conditions. The objective of this in vitro study was to evaluate the performance of the Enlite® Sensor when connected to either the iPro™ Continuous Glucose Monitor recording device or the Guardian® REAL-Time transmitting device, in hypobaric and hyperbaric conditions. METHODS Sixteen sensors connected to eight iPro devices and eight Guardian REAL-Time devices were immersed in three beakers containing separate glucose concentrations: 52, 88, and 207 mg/dl (2.9, 4.9, and 11.3 mmol/liter). Two different pressure tests were conducted: a hypobaric test, corresponding to maximum 18000 ft/5500 m height, and a hyperbaric test, corresponding to maximum 100 ft/30 m depth. The linearity of the sensor signals in the different conditions was evaluated. RESULTS The sensors worked continuously, and the sensor signals were collected without interruption at all pressures tested. When comparing the input signals for glucose (ISIGs) and the different glucose concentrations during altered pressure, linearity (R(2)) of 0.98 was found. During the hypobaric test, significant differences (p < .005) were seen when comparing the ISIGs during varying pressure at two of the glucose concentrations (52 and 207 mg/dl), whereas no difference was seen at the 88 mg/dl glucose concentration. During the hyperbaric test, no differences were found. CONCLUSIONS The Enlite Sensors connected to either the iPro or the Guardian REAL-Time device provided values continuously. In hyperbaric conditions, no significant differences were seen during changes in ambient pressure; however, during hypobaric conditions, the ISIG was significantly different in the low and high glucose concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy and acceptability of the 6-day Enlite continuous subcutaneous glucose sensor.

OBJECTIVE This study evaluated the performance and acceptability of the Enlite(®) glucose sensor (Medtronic MiniMed, Inc., Northridge, CA). SUBJECTS AND METHODS Ninety adults with type 1 or type 2 diabetes wore two Enlite sensors on the abdomen and/or buttock for 6 days and calibrated them at different frequencies. On Days 1, 3, and 6, accuracy was evaluated by comparison of sensor glucose va...

متن کامل

Effects of Influence Parameters on Color Formation in Glucose Syrups during Storage

Effects of pH, temperature, and syrup concentration on color formation in glucose syrups were studied and the shelf life of syrups under various conditions was estimated. Temperatures of 5, 25, and 45 ºC, pH values of 4, 5, and 6 as well as concentrations of 30, 40, 50, 60, 70, and 80 ºBrix were examined. After 26 weeks no significant color changes were observed at 5 ºC. At 45 ºC, color formati...

متن کامل

Investigating the relationship between ground-level particulate matter and aerosol optical depth during dust storm episodes: a case study of Tehran

Background and Objective: During the last few years, air pollution and increasing levels of particulate matters (PMs) have become major public health issues in the megacity of Tehran. The high cost of constructing and maintaining air pollution monitoring stations has made it difficult to achieve adequate spatial-temporal coverage of PM data over various regions. In this regard, the use of remot...

متن کامل

Effect of High intensity interval training and hypobaric hypoxia on Body weight changes and Endurance performance in Male wistar rats following the tapering program

Introduction: Adaptation to attitude is a complementary exercise to increase athletes' fitness and physiological performance. The present study investigated the effect of high intensity interval training at the hypobaric hypoxia conditions on weight changes and endurance performance test in rats following a three-weeks tapering period. Materials and Methods: In this experimental study, 25 m...

متن کامل

A field study on glucose, non-esterified fatty acids, beta-hydroxybutyrate and thyroid hormones in dairy cows during the breeding period in Fars province, Iran

Background: It was hypothesized that under apparently good management practices in dairy farms, some cows may not be metabolically perfect during the breeding period and this may affect their performance. Aims: This study was conducted to assess probable metabolic drawbacks in mid-lactation dairy cows affecting their performance. Methods: Thirt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 6 6  شماره 

صفحات  -

تاریخ انتشار 2012