Insert earphone depth and the occlusion effect.
نویسندگان
چکیده
Twenty individuals were tested to determine the occlusion effect caused by supraaural earphones and by insert earphones with shallow and deep insertion of its foam eartip. The bone-conduction oscillator was placed both on the forehead and the mastoid. It was concluded that using deeply inserted earphones is the most practical way in which to carry out clinical bone-conduction measurements.
منابع مشابه
Effects of background noise on earphone thresholds.
Real-ear attenuation at threshold (REAT) and monaural pure-tone thresholds were determined for normally hearing adults using a supra-aural, Audiocup, and insert earphone. The thresholds were obtained in quiet and in background noises approximating the maximum permissible ambient noise levels (MPANLs) allowed in an audiometric test room specified by ANSI S3.1-1991 and OSHA (1983). The supra-aura...
متن کاملReference equivalent threshold levels for pure tones and 1/3-oct noise bands: insert earphone and TDH-49 earphone.
Reference equivalent threshold sound pressure levels (RETSPLs) were determined for 20 subjects for pure tones and 1/3-oct noise bands. Two transducers were used: a Telephonics TDH-49 earphone mounted in an MX-41/AR cushion, and a Danavox SMW insert earphone coupled to an "HA-2" earmold. RETSPLs for pure tones transduced by the TDH-49 earphone were very similar to those published previously. For...
متن کاملReference threshold levels for an ER-3A insert earphone.
The purpose of this study was to obtain normal hearing thresholds for an ER-3A insert earphone as a contribution for future standardization and for comparison with previous studies and interim ANSI and ISO insert earphone reference equivalent threshold sound pressure levels (RETSPLs). Hearing thresholds were obtained on each ear of 48 normal-hearing subjects from 125 to 8000 Hz using ER-3A and ...
متن کاملAcoustic mechanisms that determine the ear-canal sound pressures generated by earphones.
In clinical measurements of hearing sensitivity, a given earphone is assumed to produce essentially the same sound-pressure level in all ears. However, recent measurements [Voss et al., Ear and Hearing (in press)] show that with some middle-ear pathologies, ear-canal sound pressures can deviate by as much as 35 dB from the normal-ear value; the deviations depend on the earphone, the middle-ear ...
متن کاملHigh-frequency thresholds: circumaural earphone versus insert earphone.
Benefits of high-frequency audiometry in monitoring hearing sensitivity of patients administered ototoxic medications are well established. High-frequency thresholds have been reported to be variable, due in part to small differences in the placement of the earphone diaphragm over the opening of the ear canal. Reliability may be improved by using insert earphones (ER-2) when obtaining high-freq...