Fermi function constrained deconvolution underestimates myocardial blood flow and myocardial perfusion reserve regardless of saturation correction of arterial input curve
نویسندگان
چکیده
Background Myocardial blood flow (MBF) can be quantified from arterial input function (AIF) and myocardial output function in perfusion MRI by using tracer kinetic modeling. Fermi function constrained deconvolution has been widely used to determine MBF and myocardial perfusion reserve (MPR). However, stress MBF and MPR in healthy subjects quantified by the Fermi deconvolution approach were reported to be 2 to 3 mL/min/g and 2 to 3, respectively, which are substantially smaller than those quantified by O-water PET (3 to 5 mL/min/g and 3 to 5, respectively). Tissue compartment model analysis with Patlak plot is an alternative approach to estimate MBF and MPR. In a recent study employing corrections for AIF saturation and extraction fraction of gadolinium contrast medium, MBF and MPR by model-based Patlak plot method showed an excellent agreement with those quantified by O-water PET. In the current study, we compare MBF and MPR calculated by Fermi function constrained deconvolution with those by model-based Patlak plot method.
منابع مشابه
Fully automated pixel-wise myocardial blood flow quantification with first-pass perfusion CMR
Methods Rest and adenosine stress perfusion imaging was performed on 17 normal volunteers. A saturation recovery SSFP dual-sequence technique was used to acquire three myocardial slices and an arterial input function (AIF) image series. A proton-density weighted image was acquired at the beginning of each series. Fully quantitative perfusion pixel maps were generated by an automated processing ...
متن کاملMeasurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus
BACKGROUND Mathematical modeling of cardiovascular magnetic resonance perfusion data allows absolute quantification of myocardial blood flow. Saturation of left ventricle signal during standard contrast administration can compromise the input function used when applying these models. This saturation effect is evident during application of standard Fermi models in single bolus perfusion data. Du...
متن کاملQuantitative myocardial perfusion performs as well as visual analysis in diagnosing myocardial ischaemia: a CE-MARC sub-study
Methods This was a retrospective study using a 128 patient subsample of patients, selected from the CE-MARC study such that the distribution of risk factors and disease status within the sample was representative of the full study population. Both visual and quantitative analysis were carried out using the AHA standardised 16 segment model. Visual analysis was part of the original CE-MARC study...
متن کاملComparison of single to dual bolus MR myocardial perfusion imaging for detection of coronary artery disease
Introduction Absolute myocardial perfusion can be determined using first pass MR myocardial perfusion imaging with a Fermi-model constrained deconvolution [1]. In the analysis, a linear relationship between contrast concentration and signal intensity is mostly assumed. However, at high contrast concentration saturation effects cause a non linear effect. As low contrast concentrations limits the...
متن کاملVoxel-wise quantification of myocardial blood flow with cardiovascular magnetic resonance: effect of variations in methodology and validation with positron emission tomography
BACKGROUND Quantitative assessment of myocardial blood flow (MBF) from cardiovascular magnetic resonance (CMR) perfusion images appears to offer advantages over qualitative assessment. Currently however, clinical translation is lacking, at least in part due to considerable disparity in quantification methodology. The aim of this study was to evaluate the effect of common methodological differen...