Non-contact breath sensor based on a Doppler detector

نویسنده

  • Z. R. Szczepaniak
چکیده

Respiratory activity is an important parameter for observation of human body activity. A normal adult has a respiratory rate of 12–15 breaths/min in normal conditions. Breath sensor based on non-contact Doppler detector allows for the measurement and detection and the absence of the breathing action, which may cause death in a few minutes. The monitoring and detection of some respiratory abnormality presents interest in certain situations (i.e. patients from intensive therapy, of newborn children and many others). The paper covers a new technical solution of the low-cost breath sensor, which consists of the microwave generator together with a resonant patch antenna. There is only one antenna for transmitting and receiving. The technical solution of the oscillator is based on a single FET transistor. The microwave oscillator may be tuned by change of the antenna dimensions. The solution presented here is designed for 2.4GHz (ISM band). The respiratory activity is mainly detected due to the motion of the body. The wave reflected by the moving body surface is mixed with the oscillating frequency by FET transistor junction. Filtering the low frequency signals gives a component that represents the Doppler frequency due to body surface motion. Next, it is processed with high a resolution analogue-digital converter and digitally filtered, and time-frequency analyzed as well. The processing enables the detection of the respiration rate with accuracy 1 beat/min or 0.016Hz. Signal processing in digital domain includes removal of DC offset and out-of-band noise. Experimental results confirm the possibility of using a microwave Doppler detector to measure and analyze respiratory activity signals. This method permits to measure the breathing rate period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contact-free Estimation of Respiration Rates during Sleep

A 5.8GHz multi-channel Doppler radar bio-motion sensor for contact-less and convenient measurement of respiration rate in the home was developed and used to measure respiration of a subject. This paper reports on the accuracy of the non-contact sensor respiration rate estimates obtained using signal processing methods compared to a gold standard reference of expert manually scored respiration r...

متن کامل

Design and Modeling of a New Type of Tactile Sensor Based on the Deformation of an Elastic Membrane

This paper presents the design and modeling of a flexible tactile sensor, capable of detecting the 2D surface texture image, contact-force estimation and stiffness of the sensed object. The sensor is made of polymer materials. It consists of a cylindrical chamber for pneumatic actuation and a membrane with a mesa structure. The inner radius of the cylindrical chamber is 2cm and its outer radius...

متن کامل

General Linear Chirplet Transform and Radar Target Classification

In this paper, we design an attractivealgorithm aiming to classify moving targets includinghuman, animal, vehicle and drone, at groundsurveillance radar systems. The non-stationary reflectedsignal of the targets is represented with a novelmathematical framework based on behavior of thesignal components in reality. We further propose usingthe generalized linear chirp transform for the analysisst...

متن کامل

Design and Construction of a Novel Tactile Sensor for Measuring Contact-Force, Based on Piezoelectric Effect

In this paper, design and construction of a tactile sensor for measuring contact-force is presented. Mechanism of measuring contact-force in this tactile sensor is based on impedance changing of piezoelectric crystal and voltage of different points in circuit as a result of applying force on the crystal. By considering a specific point in the circuit and recording the changes of its voltage, ma...

متن کامل

An Ultrasonic Contactless Sensor for Breathing Monitoring

The monitoring of human breathing activity during a long period has multiple fundamental applications in medicine. In breathing sleep disorders such as apnea, the diagnosis is based on events during which the person stops breathing for several periods during sleep. In polysomnography, the standard for sleep disordered breathing analysis, chest movement and airflow are used to monitor the respir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011