Noise analysis in magnetic resonance electrical impedance tomography at 3 and 11 T field strengths.

نویسندگان

  • Rosalind Sadleir
  • Samuel Grant
  • Sung Uk Zhang
  • Byung Il Lee
  • Hyun Chan Pyo
  • Suk Hoon Oh
  • Chunjae Park
  • Eung Je Woo
  • Soo Yeol Lee
  • Ohin Kwon
  • Jin Keun Seo
چکیده

In magnetic resonance electrical impedance tomography (MREIT), we measure the induced magnetic flux density inside an object subject to an externally injected current. This magnetic flux density is contaminated with noise, which ultimately limits the quality of reconstructed conductivity and current density images. By analysing and experimentally verifying the amount of noise in images gathered from two MREIT systems, we found that a carefully designed MREIT study will be able to reduce noise levels below 0.25 and 0.05 nT at main magnetic field strengths of 3 and 11 T, respectively, at a voxel size of 3 x 3 x 3 mm(3). Further noise level reductions can be achieved by optimizing MREIT pulse sequences and using signal averaging. We suggest two different methods to estimate magnetic flux noise levels, and the results are compared to validate the experimental setup of an MREIT system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic resonance electrical impedance tomography at 3 Tesla field strength.

Magnetic resonance electrical impedance tomography (MREIT) is a recently developed imaging technique that combines MRI and electrical impedance tomography (EIT). In MREIT, cross-sectional electrical conductivity images are reconstructed from the internal magnetic field density data produced inside an electrically conducting object when an electrical current is injected into the object. In this ...

متن کامل

Magnetic Resonance Electrical Impedance Tomography (MREIT) at 11 Tesla Field Strength: Preliminary Experimental Study

We present a preliminary experimental study of electrical conductivity imaging using an 11T Magnetic Resonance Electrical Impedance Tomography (MREIT) system. The primary goal was to evaluate the noise level in measured magnetic flux density data subject to an injection current. We found that the noise level from the 11T system is about 0.2nT whereas it is about 1.4nT using a 3T system. MREIT c...

متن کامل

Feasibility Study of MREIT in Clinical Applications

Introduction Several in vitro studies have shown that the electrical impedance of malignant tissues is significantly higher than those of normal and benign tissues. Therefore, impedance imaging has the potential as a diagnostic tool in cancer. Magnetic Resonance Electrical Impedance Tomography (MREIT) is a technique that is used for imaging impedance distribution inside an object noninvasively ...

متن کامل

A uniqueness result and image reconstruction of the orthotropic conductivity in magnetic resonance electrical impedance tomography

The Magnetic resonance electrical impedance tomography (MREIT) is a new medical imaging method combining electrical impedance tomography (EIT) and current injection MRI technique. In this paper, we show the uniqueness in MREIT problem with an orthotropic conductivity under the hypothesis that the ratios of conductivities are known. Based on an effective numerical differentiation method and an a...

متن کامل

A feasibility study of magnetic resonance driven electrical impedance tomography using a phantom.

Imaging the electrical properties of human tissue may aid in cancer diagnoses or monitoring organ function. Traditionally, the electrical properties are revealed with electrical impedance tomography, where currents are injected into human tissue and voltages are measured on the surface. This paper focuses on a method of measuring the electrical properties using a magnetic resonance (MR) scanner...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 26 5  شماره 

صفحات  -

تاریخ انتشار 2005