Automated mass spectral deconvolution and identification system for GC-MS screening for drugs, poisons, and metabolites in urine.
نویسندگان
چکیده
BACKGROUND The challenge in systematic toxicological analysis using gas chromatography and/or liquid chromatography coupled to mass spectrometry is to identify compounds of interest from background noise. The large amount of spectral information collected in one full-scan MS run demands the use of automated evaluation of recorded data files. We evaluated the applicability of the freeware deconvolution software AMDIS (Automated Mass Spectral Deconvolution and Identification System) for GC-MS-based systematic toxicological analysis in urine for increasing the speed of evaluation and automating the daily routine workload. METHODS We prepared a set of 111 urine samples for GC-MS analysis by acidic hydrolysis, liquid-liquid extraction, and acetylation. After analysis, the resulting data files were evaluated manually by an experienced toxicologist and automatically using AMDIS with deconvolution and identification settings previously optimized for this type of analysis. The results by manual and AMDIS evaluation were then compared. RESULTS The deconvolution settings for the AMDIS evaluation were successfully optimized to obtain the highest possible number of components. Identification settings were evaluated and chosen for a compromise between most identified targets and general number of hits. With the use of these optimized settings, AMDIS-based data analysis was comparable or even superior to manual evaluation and reduced by half the overall analysis time. CONCLUSIONS AMDIS proved to be a reliable and powerful tool for daily routine and emergency toxicology. Nevertheless, AMDIS can identify only targets present in the user-defined target library and may therefore not indicate unknown compounds that might be relevant in clinical and forensic toxicology.
منابع مشابه
Clinical Validation of a Highly Sensitive GC-MS Platform for Routine Urine Drug Screening and Real-Time Reporting of up to 212 Drugs
An important role of the clinical toxicology laboratory is to provide continuous diagnostic testing for patients with altered mental status and for other medical indications. To meet these needs, we have developed a new Gas Chromatography-Mass Spectrometry (GC-MS) platform that facilitates routine screening and automated reporting of 212 drugs by laboratory technologists around the clock withou...
متن کاملScreening for 171 Volatile Organic Air Pollutants Using GC/MS with Deconvolution Reporting Software and a New Indoor Air Toxics Library Application
A retention-time-locked mass spectral database was created specifically for indoor air analysis by thermal desorption/gas chromatography/mass spectroscopy (TD/GC/MS). This Indoor Air Toxics Database contains locked retention times and mass spectra for 171 volatile and semivolatile organic compounds that are targets in various indoor air methods. In combination with Agilent's Deconvolution Repor...
متن کاملDereplication of Natural Products Using GC-TOF Mass Spectrometry: Improved Metabolite Identification by Spectral Deconvolution Ratio Analysis
Dereplication based on hyphenated techniques has been extensively applied in plant metabolomics, thereby avoiding re-isolation of known natural products. However, due to the complex nature of biological samples and their large concentration range, dereplication requires the use of chemometric tools to comprehensively extract information from the acquired data. In this work we developed a reliab...
متن کاملScreening for Pesticides in Food Using the Japanese Positive List Pesticide Method: Benefits of Using GC/MS with Deconvolution Reporting Software and a Retention Time Locked Mass Spectral Database Application
In 2006, the Japanese Ministry of Health, Labour and Welfare introduced a new system for the regulation of pesticides, feed additives, and veterinary drugs. This “Positive List” system stipulates that only compounds on the approved list can be used in food production and provides the framework for regulation of these compounds. These new regulations have increased the need for analytical method...
متن کاملIdentification of Volatile Organic Compounds from Trichoderma virens (6011) by GC-MS and Separation of a Bioactive Compound via Nanotechnology
Fungal volatile organic compounds (VOCs) have the potential of being used as biocontrol agents for biotechnological applications in agriculture, industry and medicine. In this research, different VOCs from secondary metabolites of biocontrol fungus Trichoderma virens (6011) KP671477 were separated using n-hexane, n-butanol and methanol solvents and identified by gas chromatography–mass spectrom...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 56 4 شماره
صفحات -
تاریخ انتشار 2010