Optimal single intraocular lens power for the Nepali population.
نویسندگان
چکیده
AIM To evaluate optimal standard intraocular lens power for Nepalese eye camp cataract patients. METHOD A retrospective case series of 5109 preoperative cataract patients. RESULTS Average axial length of 23.08 (SD 1.26). Average dioptre intraocular lens power 21.37 (3.04). CONCLUSION An increase in the intraocular lens power used at Nepalese eye camps from +21.0 to 22.5 dioptres would improve overall visual outcome.
منابع مشابه
مقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملPrediction of Refractive Outcome of Second Eye with Partial Adjustment of Intraocular Lens Power of the First Eye
Background and Objective: This study aimed at comparing the results of refractive cataract surgery in patients undergoing sequential surgeries in both eyes. Considering the preoperative refraction and final refraction of the first eye, it is possible to correct the refrative result of cataract surgery using the adjustment of the second eye intraocular lens (IOL) power. Materials and Methods: T...
متن کاملVisual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus
Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...
متن کاملInfluence of corneal power on intraocular lens power of the second eye in the SRK/T formula in bilateral cataract surgery
BACKGROUND To evaluate the effect of different adjustments of the refractive outcome of the first eye according to corneal power (K) in order to improve the intraocular lens (IOL) power calculation of the second eye in the SRK/T formula. METHODS One hundred thirty-four patients who underwent uncomplicated bilateral, sequential phacoemulsification with AcrySof IQ implantation were enrolled. Th...
متن کاملIntraocular lens power calculation following laser refractive surgery
Refractive outcomes following cataract surgery in patients that have previously undergone laser refractive surgery have traditionally been underwhelming. This is related to several key issues including the preoperative assessment (keratometry) and intraocular lens power calculations. Peer-reviewed literature is overwhelmed by the influx of methodology to manipulate the corneal or intraocular le...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 88 10 شماره
صفحات -
تاریخ انتشار 2004