Assessment of accuracy and applicability of a new electronic peak flow meter and asthma monitor.
نویسندگان
چکیده
The aim of this study was to assess the accuracy and applicability of a portable electronic peak flow meter combined with an asthma monitor (AM1, Jaeger, Germany) which measures peak expiratory flow (PEF), forced expiratory volume in one second (FEV1) and forced vital capacity (FVC). The technical accuracy in PEF, FEV1 and FVC measurement was tested according to American Thoracic Society (ATS) criteria for monitoring devices using a flow generator. In addition, the effect of connecting a heated screen pneumotachograph (PT) to the AM1 was determined and the accuracy in FEV1 determinations was evaluated by simultaneous measurements in 49 normal volunteers. The devices tested fulfilled all ATS criteria for monitoring devices with respect to the accuracy of PEF, FEV1, and FVC measurements. The conditions of intra- and interdevice variability were satisfied in all cases. Compared with the PT, the AM1 showed about 4% lower values in FEV1, as measured in the 49 subjects. In conclusion, the electronic peak flow meter and asthma monitor AM1 yielded valid measurements of peak expiratory flow and forced expiratory volume in one second, which matched the accuracy criteria of the American Thoracic Society standards for monitoring devices.
منابع مشابه
Peak flow diaries in childhood asthma are unreliable.
BACKGROUND A study was undertaken to investigate the compliance with and accuracy of peak flow diaries in childhood asthma. METHODS Forty asthmatic children (5-16 years) were asked to perform peak flow measurements twice daily for 4 weeks by means of an electronic peak flow meter and to record values in a written diary. Patients and parents were unaware that the device stored the peak flow va...
متن کاملPeak Expiratory Flow Rate in Healthy Children from Tehran
Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines. Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...
متن کاملتأثیر آموزش استفاده از پیکفلومتر و پیگیری با پیامک، بر خودکنترلی بیماری آسم
Background & Aim: Asthma is one of the most prevalent chronic diseases worldwide. About 6.5 million people suffer from asthma in Iran. The Effective strategy to control asthma is related to education. The self-management has a major role in the standard education program. This study aimed to assess the effect of education on using peak flow meter and follow up via SMS on asthma self management....
متن کاملAssessment of accuracy and applicability of a portable electronic diary card spirometer for asthma treatment.
A pocked-sized turbine flowmeter and spirometer device, integrated with an electronic diary card (EDC-spirometer, Micro Medical, U.K.), was tested with a mechanical calibrator, in an outpatient clinic and in the home situation. A screen pneumotachometer was used as flow and volume reference. Ten devices were tested; interdevice variability was small with a mean variation coefficient of 1.1% for...
متن کاملNormal measurement of peak expiratory Flow rate in the high school children in Babol, north of Iran
Background: Peak Expiratory Flow Rate (PEFR) is recommended as a tool for control of asthma. The purpose of this study was to determine the normal value of PEFR in the healthy high school children in Babol, Iran. Methods: This study was conducted on 470 healthy high school children (285 girls, 185 boys with the age between 14-18 years). For the determination of PEFR we used Mini Wright Peak Flo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The European respiratory journal
دوره 12 2 شماره
صفحات -
تاریخ انتشار 1998