Effect of tracheal suctioning on aspiration past the tracheal tube cuff in mechanically ventilated patients

نویسندگان

  • Pascal Beuret
  • Bénédicte Philippon
  • Xavier Fabre
  • Mahmoud Kaaki
چکیده

UNLABELLED BACKGROUND This clinical study evaluated the effect of a suctioning maneuver on aspiration past the cuff during mechanical ventilation. METHODS Patients intubated for less than 48 hours with a PVC-cuffed tracheal tube, under mechanical ventilation with a PEEP ≥5 cm H2O and under continuous sedation, were included in the study. At baseline the cuff pressure was set at 30 cm H2O. Then 0.5ml of blue dye diluted with 3 ml of saline was instilled into the subglottic space just above the cuff. Tracheal suctioning was performed using a 16-French suction catheter with a suction pressure of - 400 mbar. A fiberoptic bronchoscopy was performed before and after the suctioning maneuver, looking for the presence of blue dye in the folds within the cuff wall or in the trachea under the cuff. The sealing of the cuff was defined by the absence of leakage of blue dye either in the cuff wall or in the trachea under the cuff. RESULTS Twenty-five patients were included. The size of the tracheal tube was 7-mm ID for 5 patients, 7.5-mm ID for 16 patients, and 8-mm ID for four patients. Blue dye was never seen in the trachea under the cuff before suctioning and only in one patient (4%) after the suctioning maneuver. Blue dye was observed in the folds within the cuff wall in 6 of 25 patients before suctioning and 11 of 25 after (p = 0.063). Overall, the incidence of sealing of the cuff was 76% before suctioning and 56% after (p = 0.073). CONCLUSIONS In patients intubated with a PVC-cuffed tracheal tube and under mechanical ventilation with PEEP ≥5 cm H2O and a cuff pressure set at 30 cm H2O, a single tracheal suctioning maneuver did not increase the risk of aspiration in the trachea under the cuff. TRIAL REGISTRATION ClinicalTrials.gov, number NCT01170156.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level

Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...

متن کامل

Effects of expiratory rib cage compression combined with endotracheal suctioning on gas exchange in mechanically ventilated rabbits with induced atelectasis.

INTRODUCTION In Japan, expiratory rib cage compression (a chest physiotherapy technique) is frequently used with mechanically ventilated patients. It has not been determined whether rib cage compression combined with endotracheal suctioning improves oxygenation, ventilation, and mucus clearance. We evaluated the effects of rib cage compression with and without endotracheal suctioning on P(aO(2)...

متن کامل

Endotracheal tube cuff pressure: need for precise measurement.

CONTEXT High compliance endotracheal tubes cuffs are used to prevent gas leak and also pulmonary aspiration in mechanically ventilated patients. However, the use of the usual cuff inflation volumes may cause tracheal damage. OBJECTIVE We tested the hypothesis that endotracheal tube cuff pressures are routinely high (above 40 cmH2O) in the Post Anesthesia Care Unit (PACU) or Intensive Care Uni...

متن کامل

A 72-hour study to test the efficacy and safety of the "Mucus Slurper" in mechanically ventilated sheep.

OBJECTIVE In patients intubated with endotracheal tubes (ETTs), suctioning is routinely performed to remove mucus from within the ETT and trachea. The Mucus Slurper is a novel ETT with built-in suction ports arranged radially at its tip. We evaluated the safety and efficacy of the Mucus Slurper, compared with conventional tracheal suction, to prevent airway obstruction in sheep with the ETT and...

متن کامل

استفاده‌ از نرمال‌ سالین‌ در ساکشن‌ لوله‌ تراشه‌ بر گازهای‌ خون‌ شریانی‌

  Background : Disorder in diffusion of blood gases almost always is clue to collection of secretion in respiratory airways. So protecting the airway, correct suctioning to remove the secretion and maintenance of air way potency are necessary interventions in patient with end tracheal tube .   Objective : To determine and compaire arterial blood gas in patient with open heart surgery with and w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2012