High-throughput array production using precision glass syringes.
نویسندگان
چکیده
The advantages of using 1, 96, or 384 precision glass syringes in automated high-throughput microdispensers in creating highly uniform and reproducible DNA, protein, and organic compound array filters and slides are described. Using the Hydra Microdispenser and Tango Liquid Handling system, 0.1-5 ng (in 50-300 nL) PCR-amplified, human cancer-related genes and housekeeping genes were spotted onto nylon membranes and coated slides. Protein solutions of 50 microg/mL to 1 mg/mL were spotted onto coated slides or onto MaxiSorp 96-well plates. Up to 6144 spots/membrane and up to 1000 spots/slide were printed. The size of the spots created by glass syringes was uniform and reproducible (precision variation of less than 5%) from spot to spot and membrane to membrane. Using a Tango 384 system, a total of ten 6144-spot filters can be produced in approximately 25 min, translating into a spotting speed of 2.5 min/membrane.
منابع مشابه
DNA sequencing using rolling circle amplification and precision glass syringes in a high-throughput liquid handling system.
An automated high-throughput method that employs rolling circle amplification (RCA) to generate template for large-scale DNA sequencing has been developed using liquid handling systems equipped with precision glass syringes. A protocol was designed to perform the sequencing analysis from template preparation to thermal cycle sequencing within the same vessel, thus minimizing the amount of liqui...
متن کاملDesign and fabrication of low-cost thermal imaging optics using precision chalcogenide glass molding
Aspheric and diffractive surfaces in infrared materials are traditionally fabricated by single point diamond turning, which is a high-cost, low-throughput process, not suitable for low-cost, high-volume applications. Precision molding of chalcogenide glasses is a novel process we developed to allow the efficient fabrication of quality infrared optics in large volumes. In this paper we present t...
متن کاملFabrication of conical microneedles array using photolithography
Background and Aim: Microneedle technology has led to huge changes in the field of drug delivery medicine. Using microneedles, the drug can be injected locally, painlessly, and in very low and controlled doses with high precision. Local drug delivery through the skin with microneedles has many advantages over other methods of drug delivery. In this method, the drug does not enter the gastrointe...
متن کاملUse of glass capillaries avoids the time changes in high blood PO(2) observed with plastic syringes.
STUDY OBJECTIVES In adults, arterial blood samples are usually drawn using plastic syringes. In contrast to glass syringes, plastic syringes let oxygen diffuse through their wall. This results in PO(2) changes during storage, especially when PO(2) is high. An alternative to glass syringes is the Microsampler (Roche Diagnostics; Schaffhausen, Switzerland), a commercially available device consist...
متن کاملEffects of sample storage time, temperature and syringe type on blood gas tensions in samples with high oxygen partial pressures.
BACKGROUND Although plastic arterial sampling syringes are now commonly used, the effects of sample storage time and temperature on blood gas tensions are poorly described for samples with a high oxygen partial pressure (PaO2) taken with these high density polypropylene syringes. METHODS Two ml samples of tonometered whole blood (PaO2 86.7 kPa, PaCO2 4.27 kPa) were placed in glass syringes an...