The quantitative measurement of electrolyte elements in nuclei of maturing erythrocytes of chick embryo using electron-probe X-ray microanalysis.

نویسندگان

  • R T Jones
  • R T Johnson
  • B L Gupta
  • T A Hall
چکیده

Na, K and Cl measurements have been made on frozen sections of chick red blood cells throughout embryonic development, using electron-probe microanalysis. There is an apparent fluctuation in the levels of these elements during maturation, although the Na/K ratio remains fairly constant. The nuclear Na concentration resembles that of the cytoplasm, rather than that of the medium, at all stages. Inhibitor studies indicate that when cytoplasmic Na, K and Cl levels are altered, their corresponding nuclear levels are similarly affected. Additionally, the measurements in nuclei isolated in anhydrous media from lyophilized cells have shown artefactual accumulation of high Na, K, Ca and Mg.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Energy-dispersive Electron Probe X-ray Microanalysis of Individual Particles

An electron probe X-ray microanalysis (EPMA) technique using an energy-dispersive X-ray detector with an ultra-thin window, designated low-Z particle EPMA, has been developed. The low-Z particle EPMA allows the quantitative determination of concentrations of low-Z elements such as C, N, and O, as well as higher-Z elements that can be analyzed by conventional energydispersive EPMA. The quantitat...

متن کامل

Quantitative Electron-probe Microanalysis and WDS Background Measurement

The accuracy of electron-probe microanalysis (EPMA) by wavelength-dispersive spectrometry (WDS) depends critically on spectrometer alignment, specimen positioning, pulse-height (PHA) discrimination, and deadtime correction, but also on the accurate measurement of characteristic x-ray intensities (i.e., “peak”) and continuum (i.e., “background”) which form the k-ratio that is converted by correc...

متن کامل

Limitations to Accuracy in Extracting Characteristic Line Intensities From X-Ray Spectra

The early development of quantitative electron probe microanalysis, first using crystal spectrometers, then energy dispersive x-ray spectrometers (EDXS), demonstrated that elements could be detected at 0.001 mass fraction level and major concentrations measured within 2 % relative uncertainty. However, during this period of extensive investigation and evaluation, EDXS detectors were not able to...

متن کامل

Characterization of atmospheric particles by electron probe X-ray microanalysis.

Microchemical glass standards were used to validate a quantitation method based on peak-to-background (P/B) ratios from electron probe x-ray microanalysis spectra. This standardless method was applied to the determination of concentrations of individual particles from Malpha or Lalpha lines, as well as from Kalpha lines. The algorithm was tested on particulate glass samples for diameters rangin...

متن کامل

In Situ Analysis of Gut Residue of Corophium Volutator (Pallas) by Electron Probe Microanalysis after Exposure to Barytes Spiked Sediments

Corophium volutator (Pallas) has been recommended by the paris Commission as one of the standard species for testing chemical used in offshore oil and gas exploration/production. In the present study, gut contents of Corophium volutator have been analysed by electron probe microanalysis (EPMA) for BaSO4 and other heavy metal impurities after exposure tto spiked sediments followin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cell science

دوره 35  شماره 

صفحات  -

تاریخ انتشار 1979