Development of a biologically relevant dermal sampler.
نویسندگان
چکیده
There are currently no appropriate methods for measuring dermal exposure to volatile agents. To address this we have produced a prototype Institute of Occupational Medicine (IOM) dermal sampler consisting of an adsorbent sandwiched between a permeable membrane and an impervious backing. The concentration of solvent on the membrane surface may be estimated from the mass collected on the adsorbent and the known permeation rate through the membrane. We have developed the prototype IOM dermal sampler for measurement of toluene exposures. Evaluation of the prototype sampler was undertaken in two stages: laboratory performance in controlled exposure situations and two short-field evaluations, which included simultaneous measurement of inhalation exposure. In all cases we compared the prototype IOM dermal sampler with activated charcoal cloth (ACC). Laboratory trials were split into spray, pour and immersion tests. The data from these suggest that the sampler responds to concentration rather than the mass on the surface of the sampler. The field study showed that the prototype sampler was suitable for measuring dermal exposure. However, the mean permeation rate of the best membrane was 78 000 mug cm(-2) h(-1), which is higher than the permeation rate through skin. This high permeation rate created difficulties throughout the study, particularly as it allowed the adsorbent to become rapidly saturated. The prototype IOM dermal sampler is the first practical dermal exposure sampler to mimic uptake through the skin. The sampler gave reproducible results in the laboratory and field trials. Future work is required to identify a less permeable membrane, which has characteristics closer to that of human skin. Additionally, a higher capacity adsorbent would be desirable. We have demonstrated a major difference when calculating the total contribution to body burden via the dermal exposure pathway using the prototype IOM dermal sampler and ACC patches, 1.5% of the total body burden compared with 95%. The prototype IOM dermal sampler provides a more biologically relevant exposure metric than the alternatives.
منابع مشابه
Conceptual model for assessment of dermal exposure.
Dermal exposure, primarily to pesticides, has been measured for almost half a century. Compared with exposure by inhalation, limited progress has been made towards standardisation of methods of measurement and development of biologically relevant exposure measures. It is suggested that the absence of a consistent terminology and a theoretical model has been an important cause of this lack of pr...
متن کاملارزیابی عملکرد ریز نمونه بردار تله سوزنی حاوی جاذب کامپوزیت سیلیکاته نانولوله کربنی جهت نمونه برداری از پرکلرواتیلن : مطالعه آزمایشگاهی و میدانی
Background and aims: Needle trap micro-sampler, with all advantages of microextraction techniques such as solid phase microextraction, owing to the ease of use and becoming a powerful method for air pollution monitoring. In this study, the performance of needle trap micro-sampler device with silica composite of carbon nanotubes, prepared using sol-gel technique, was investigated for health moni...
متن کاملA study of nanosilver dermal toxicity in mice balb/c
As a result of growing applications of manufactured nanoparticles, there is an increasing concern aboutpossible side effects of exposure to these materials on human and environment. Nanosilver (n-Ag) has foundwide use in medical applications including development of silver-based dressings and silver-coated medicaldevices. However, toxicity of these particles clue to their dermal use has not bee...
متن کاملInactivation of the Antibacterial and Cytotoxic Properties of Silver Ions by Biologically Relevant Compounds
There has been a recent surge in the use of silver as an antimicrobial agent in a wide range of domestic and clinical products, intended to prevent or treat bacterial infections and reduce bacterial colonization of surfaces. It has been reported that the antibacterial and cytotoxic properties of silver are affected by the assay conditions, particularly the type of growth media used in vitro. Th...
متن کاملA stochastic model for the evolution of metabolic networks with neighbor dependence
MOTIVATION Most current research in network evolution focuses on networks that follow a Duplication Attachment model where the network is only allowed to grow. The evolution of metabolic networks, however, is characterized by gain as well as loss of reactions. It would be desirable to have a biologically relevant model of network evolution that could be used to calculate the likelihood of homol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of occupational hygiene
دوره 50 1 شماره
صفحات -
تاریخ انتشار 2006