Anti-islanding protection based on voltage and frequency analysis in wind turbines units

نویسندگان

  • Behrooz Sobhani
  • Noradin Ghadimi
چکیده

This paper introduces a new islanding detection algorithm method based on voltage and frequency analysis for wind turbines as distributed resource units at the distribution voltage level. The proposed method is based on processing of the rate of change of q-axis component of voltage and accelerates of change of frequency. This method detects the islanding conditions with the analysis of these signals. The studies reported in this paper are based on time-domain simulations using MATLAB, and the feasibility of the proposed method is evaluated with an experimental system. The experimental system parameters are the same as those of the simulated system. The results show that the proposed islanding detection method succeeds in detecting islanding both in the experimental and simulated systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implementation of ROCOPS Method for Anti-Islanding Protection of Wind Turbine

In recent years, based on the growing importance of clean energy in comparison with conventional energy production from fossil fuels, DG systems are gradually becoming more popular all over the world. These resources solve many problem of system. However, these resources create some other problems too. One of the most problem of DGs is unwanted islanding. This paper addresses reliable passive i...

متن کامل

A SAIWD-Based Approach for Simultaneous Reconfiguration and Optimal Siting and Sizing of Wind Turbines and DVR units in Distribution Systems

In this paper, a combination of simulated annealing (SA) and intelligent water drops (IWD) algorithm is used to solve the nonlinear/complex problem of simultaneous reconfiguration with optimal allocation (size and location) of wind turbine (WT) as a distributed generation (DG) and dynamic voltage restorer (DVR) as a distributed flexible AC transmission systems (DFACT) unit in a distribution sys...

متن کامل

Adaptive neuro-fuzzy inference system (ANFIS) islanding detection based on wind turbine simulator

This paper presents a passive islanding detection method based on means of a neuro-fuzzy approach for wind turbines. Several methods based on passive and active detection scheme have been proposed. While passive schemes have a large Non detection zone (NDZ), concern has been raised on active method due to its degrading power quality effect. Reliably detecting this condition is regarded by many ...

متن کامل

Accidental Islanding of Distribution Systems with Multiple Distributed Generation Units of Various Technologies

The system response to accidental islanding and effect on anti-islanding detection of distribution feeders with multiple distributed generation (DG) technologies (synchronous machine and inverterbased units) is one major utility concern associated with increasing penetration of DG. Studies have been conducted to evaluate the performance of anti-islanding detection through use of conventional vo...

متن کامل

A New Protection System for Islanding Detection in LV Distribution Systems

The growth of penetration of Distributed Generators (DGs) is increasing the risk of unwanted islanded operation in Low Voltage (LV) distribution systems. In this scenario, the existing anti-islanding protection systems, installed at the DG premises and based on classical voltage and frequency relays, are no longer effective, especially in the cases of islands characterized by a close match betw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013