A rapid method for the micro-estimation of lead in urine.

نویسندگان

  • J M DICK
  • R W ELLIS
  • J STEEL
چکیده

In the literature on the estimation of urinary lead, it is usually recommended that not less than 100 ml. aliquots of the urine sample be taken for analysis. This has certain disadvantages, not the least of which is the time required to ash the organic content of the urine. In addition, spot samples of urine collected from groups of workmen are often less than the 200 ml. volume required for duplicate estimations. For these reasons, a rapid and accurate method was sought for the determination of total lead in small volumes of urine. The method finally devised is based on the dithizone mono-colour method described by Fischer and Leopoldi (1940). The organic matter in a 20 ml. sample of urine is destroyed by ashing with nitric acid and the residue is dissolved in water. Bismuth is detected and removed by washing at pH 3 0-3 4 with a solution of dithizone in chloroform which is then discarded. Cyanide solution, buffered topH 10, and an alkaline solution of dithizone are added and lead is extracted as the dithizonate into chloroform. Excess dithizone is washed out of the organic phase with potassium cyanide solution. The optical density of the washed chloroform extract is directly proportional to the quantity of lead present. The advantages claimed for the method are as follows: 1. The small volume of urine needed for an accurate determination considerably reduces the time required to ash the sample and hence the time taken for the determination. 2. The ashing and extraction of lead with dithizone are carried out in the same vessel, thus reducing contamination from external sources. Apparatus

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Amphetamine and Methamphetamine by Dispersive Liquid Phase Micro-extraction: A Novel Experimental Approach

Background: A syringe to syringe dispersive liquid phase micro-extraction-floating organic drop was applied and used for the simultaneous extraction and pre-concentration of trace amounts of amphetamine (AMP) and methamphetamine (MAMP) in urine samples. The extracted analytes were determined by high performance liquid chromatography along with diode array detection. Materials & Methods: In thi...

متن کامل

Quantitative Bacterial Micro-Assay for Rapid Diagnosis of Galactosemia: Application in Galactosemia Neonatal Screening

In the present study a new economic and rapid bacterial micro-assay for simultaneous detection and quantitative measurement of serum galactose was developed. Analysis of the standard curve showed a linearity range for galactose from 2 mg/dL to 180 mg/dL with a regression equation of Y = 0.013X ? 0.083; R² = 0.962. The advantage of the method is its ability to measure serum galactose quantitativ...

متن کامل

Feasibility evaluation of trace amount of zinc in urine samples using atomic absorption solidified floating organic drop micro-extraction technique

Background: The present study was carried out with the aim of extracting trace amounts of zinc in urine samples with ultrasound-assisted emulsification solidified floating organic drop micro-extraction (USAE-SFODME) method by flame atomic absorption spectrometry (FAAS). The efficiency was investigated using the solvent extraction volume, extraction pH, time sonication and temperature extraction...

متن کامل

Interactive Effects of the Carbon Paper, Sodium Bicarbonate and Oral Contraceptive Pills on Morphine Urine Test

Abstract Background and objectives: A major problem for labs. esp. medico legal centers is drug test false positive and negative results. Using carbon paper, sodium bicarbonate or oral contraceptive pills (OCP) are common among addict people to make the results negative. Therefore, we decided to evaluate the effect of carbon paper, sodium bicarbonate or OCP on morphine urine test. Material and ...

متن کامل

آیا بیماران تالاسمیک دریافت کننده دسفرال کمبود روی دارند؟

Background and purpose: The zinc deficiency has a known side effects and zinc deficiency in Ïron is a known phenomenon. Thalassemic patients under treatment with Ïron shlator i-e Dispheral, discharge some amount of zinc. Hence zinc deficiency is a matter of thought. Ïn order to determine the relation between dispheral usage and zinc deficiency this study was conducted on the thalassemic pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of industrial medicine

دوره 18  شماره 

صفحات  -

تاریخ انتشار 1961