A Comparison of Internal Mammary Artery and Saphenous Vein Grafts After Coronary Artery Bypass Surgery

نویسنده

  • Hans L. Hillege
چکیده

Background Superior patency rates for internal mammary artery (IMA) grafts compared with vein coronary bypass grafts have been demonstrated by retrospective studies. This difference may have been affected by selection bias of patients and coronary arteries for IMA grafting. Methods and Results To estimate the difference between IMA and vein grafts, we analyzed graft patency data of 912 patients who entered a randomized clinical drug trial. In this trial, 494 patients received both IMA and vein grafts (group 1) and 418 only vein grafts (group 2). Occlusion rates of IMA grafts and IMA plus vein grafts in group 1 were compared with those of vein grafts in group 2. Multivariate analysis was used to compare occlusion rates of IMA and vein grafts while other variables related to graft patency were controlled for. In addition, 1-year clinical outcome was assessed by the incidence of myocardial infarction, thrombosis, major bleeding, and death. Occlusion rates of distal anastomoses in group 1 versus group 2 were 5.4% (IMA grafts) versus 12.7% (vein grafts) (P<.0001) and 10.4% (IMA plus vein grafts) versus 12.7% (vein grafts) (P=.14). There was no difference in adjusted risk of occlusion between IMA grafts and vein grafts (P=.089). Type and location of distal anastomosis and lumen diameter of the grafted coronary artery were shown to be predictors of occlusion. Clinical events occurred in 17.8% (group 1) and 16.0% (group 2) of patients (P=.53). Conclusions The observed difference in 1-year occlusion rates between IMA and vein grafts can be explained by a maldistribution of graft characteristics by selection of coronary arteries for IMA grafting rather than being ascribed to graft material. One-year clinical outcome is not improved by IMA grafting. (Circulation. 1994;90:2367-2374.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Major Leg Wound Complications After Saphenous Vein Harvest for Coronary Revascularization

Background: Major leg wound complications after coronary artery bypass graft procedures are infrequent and few are reported in the litrature.We present our experience in treating 30 patients with major leg wound complications after coronary revascularization procedures. Materials and Methods: A retrospective review of 2100 bypass procedures with saphenous veingraft performed over a 5-years p...

متن کامل

Role of prosthetic conduits in coronary artery bypass grafting.

Prosthetic grafts are required for coronary artery bypass grafting (CABG) when the availability of suitable autologous conduits is limited. The ideal cardiovascular bypass graft requires a broad range of characteristics including strength, viscoelasticity, biocompatibility, blood compatibility and biostability. Many alternative conduits have been developed and used in the past, but most of them...

متن کامل

Radial artery bypass grafts have an increased occurrence of angiographically severe stenosis and occlusion compared with left internal mammary arteries and saphenous vein grafts.

BACKGROUND The radial artery has been increasingly used in CABG. However, angiographic outcome data have been limited. METHODS AND RESULTS We reviewed all coronary angiography procedures from February 1996 to October 2001 and selected patients with a radial artery bypass graft. Angiographic outcomes were divided into groups as (1) occluded, (2) severe disease (> or =70% stenosis, or string si...

متن کامل

Radial artery versus saphenous vein patency randomized trial: five-year angiographic follow-up.

BACKGROUND Graft patency is a fundamental predictor of long-term survival after coronary artery bypass surgery. Left and right internal thoracic artery (arterial) graft patency has been shown to be superior to that of saphenous vein grafts. More recently, the radial artery has been used as an aortocoronary graft, but little is known about the midterm and long-term patency of this conduit. We pe...

متن کامل

Providing the fetus with calcium.

internal mammary grafts, and prosthetic tube grafts. The results with all these are either dismal or unknown. One other option is the use of the free internal mammary artery. This method extends the range of the grafts and gives results with an enhanced long term patency similar to those with pedicled internal mammary artery grafts,'3 but it imposes a technically awkward requirement for a proxi...

متن کامل

Comparison of Radial Artery and Saphenous Vein Composite Y Grafts during Off-pump Coronary Artery Bypass

BACKGROUND The safety and efficacy of arterial composite grafts for total arterial revascularization have been demonstrated. The saphenous vein (SV) is a widely used graft because of its accessibility, sufficient length, and ease of manipulation. Our aim was to compare mid-term outcomes of saphenous vein Y-grafts with radial artery Y-grafts joined by anastomosis to the left internal thoracic ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005