The relationship of bleb morphology and the outcome of needle revision with 5-fluorouracil in failing filtering bleb

نویسندگان

  • Yung-Sung Lee
  • Shiu-Chen Wu
  • Hsiao-Jung Tseng
  • Wei-Chi Wu
  • Shirley H.L. Chang
چکیده

To investigate the risk factors for failure of needling revision with 5-fluorouracil (5-FU) and to identify the correlation of outcomes of needling revision and the morphological features of dysfunctional filtration blebs using Moorfields bleb grading system.This retrospective, nonrandomized, comparative case-control study included 41 consecutive patients (41 eyes) who underwent 5-FU needling revision for failed or failing filtration blebs between July 2012 and August 2014 in Chang Gung Memorial Hospital, a referral center in Taiwan. The main outcome measures were the bleb survival and the correlation factors of bleb morphology before revision. The secondary outcome measure was the identification of any study factor associated with bleb failure.Forty-one eyes of 41 patients were included in this study. The most frequent glaucoma diagnoses were 10 cases (24%) of neovascular glaucoma and 8 cases (19%) of chronic open-angle glaucoma. Survival of bleb at 6, 12, and 24 months was 42%, 39%, and 23%. Fourteen cases (34%) maintained overall success at the last follow-up, with an average follow-up of 22.7 ± 9.4 months (range: 12-48 months). The central bleb area and height were significantly different between the successful needling group and the failed needling group (P = 0.03 and 0.04, respectively). Further trend test confirmed that smaller central bleb extension and flatter height were associated with a higher chance of failure (P = 0.02 and 0.02, respectively). Time from initial trabeculectomy to needling of less than 4 months and higher intraocular pressure (IOP) in the first postoperative week also led to significantly higher risk for failure (P = 0.01 and 0.03, respectively).A small central area and the flat height of dysfunctional blebs were more likely to fail after the needle revision. Cautious case selections, taking account of the time from the initial filtering surgery and postoperative IOP, may improve the surgical outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Needle revision of late failing filtering blebs after glaucoma surgery].

PURPOSE To evaluate the results of bleb needling in eyes subjected to filtering surgery six months or more previously. METHODS A retrospective study of 23 eyes in 21 patients subjected to bleb needling performed by means of a 25G needle, 6 months to 23 years after failed filtering surgery (mean 67.3 months). The mean number of bleb needlings was 1.2 and the mean number of 5-fluorouracil subco...

متن کامل

Needle Revision With 5-fluorouracil for the Treatment of Ahmed Glaucoma Valve Filtering Blebs: 5-Fluoruracil Needling Revision can be a Useful and Safe Tool in the Management of Failing Ahmed Glaucoma Valve Filtering Blebs.

PURPOSE To determine the outcome of needling with adjunctive 5-fluorouracil (5-FU) in patients with a failing Ahmed glaucoma valve (AGV) implant, and to identify predictors of long-term intraocular pressure (IOP) control. METHODS A prospective observational study was performed on consecutive patients with medically uncontrolled primary open-angle glaucoma (POAG) with AGV encapsulation or fibr...

متن کامل

Late-onset bleb leaks after glaucoma filtering surgery.

OBJECTIVE To determine the incidence of focal, late-onset, conjunctival bleb leaks after glaucoma filtering surgery. DESIGN Prospective, cross-sectional analysis. SETTING Tertiary care outpatient referral center. PATIENTS Consecutive patients who underwent glaucoma filtering surgery prior to June 1996 presenting for evaluation from September 2,1996, through November 15,1996. Five hundred ...

متن کامل

Sutureless revision of overhanging filtering blebs.

We describe methods and outcomes of a technique for sutureless surgical revision of symptomatic corneal overhanging filtering blebs after trabeculectomy using mitomycin in 6 eyes in 6 patients. Separation of the bleb from the corneal surface was achieved by blunt or sharp dissection, as necessary, and the overhanging portion of the bleb was excised and a bandage contact lens was inserted. Outco...

متن کامل

Efficacy of repeated 5-fluorouracil needling for failing and failed filtering surgeries based on simple gonioscopic examination

PURPOSE To evaluate the success rate of a modified bleb needling technique in eyes with previous glaucoma surgery that had elevated intraocular pressure. METHODS A retrospective study of 24 eyes of 24 patients that underwent repeated bleb needling performed for failing and failed blebs on slit lamp with 5-fluorouracil (5-FU) injections on demand. This was performed after gonioscopic examinati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016