Four-Dimensional LV Tissue Tracking from Tagged MRI with a 4D B-Spline Model
نویسندگان
چکیده
Accurate delineation of the volumetric motion of left ventri-cle (LV) of the heart over time from tagged MRI is an important area of research. We have built a system that takes tagged short-axis (SA) and long-axis (LA) image sequences as input, ts a 4D B-spline model to the LV of the heart by simultaneously tting knot solids to the SA and LA frame sequences via matching 3 sequences of model knot planes to LV tag planes for 4D tracking. The advantage of the 4D model is that 3D material point localization and displacement reconstruction is achieved in a single step. The generated 3D displacement elds are validated with a cardiac motion simulator, and 3D motion elds capturing in-vivo deformations in a parcine model of a LV with postero-lateral myocardial infarction are illustrated.
منابع مشابه
Use of a 4D planispheric transformation for the tracking and the analysis of LV motion with tagged MR images
A major issue in cardiac imaging is the assessment of cardiac function and particularly the identi cation of ischemic or infarcted tissues. We present in this article a method to reconstruct the displacement eld of the left ventricular (LV) motion using 4D planispheric transformations of time and space combined in a rst step with B-spline tensor products. Because of the 4D modeling, a) it is po...
متن کاملVolumetric Motion Tracking of Left-Ventricle of the Heart from Tagged MRI by a B-Spline Solid Model
Accurate delineation of the volumetric motion of Left-Ventricle (LV) of the heart from magnetic resonance imaging is an important area of research. We have built a system that takes tagged short-axis (SA) and long-axis (LA) image sequences as input, ts a 3D B-spline solid model to the LV of the heart by matching 3 sequences of solid knot planes to 3 sequences of tag planes, and volumetrically t...
متن کاملIn-Vivo Validation of 4D B-Spline-based Motion Tracking Algorithm for Cardiac Tagged MRI
Introduction In cardiac MRI, tags move with the contracting heart, and their distortion in subsequent images provides useful qualitative and quantitative information about functional properties of underlying myocardium [1]. We have previously reported a method to derive the heart motion from one dimensional tag displacement information [2]. In this method, a final four-dimensional tensor produc...
متن کاملRapid 3D LV Strain Reconstruction from Tagged Cardiac MR Images
X. Deng, T. S. Denney Jr Auburn University, Auburn, Alabama, United States Synopsis We present a rapid unsupervised method, called rapid UNTETHER, for computing three-dimensional (3D) myocardial strain from planar tagged cardiac MR images. Our method consisted of two steps: tag line tracking and strain reconstruction. The tag line tracking algorithm is based on a spatial tag detector and a modi...
متن کاملMotion Analysis of Both Ventricles Using Tagged-MRI in Paced Canine Hearts
Methods For this study, tagged MRI images (see Fig.1) were acquired from canine hearts while pacing with standard cardiac gated, breath-hold, cine SPGR, no echo sharing or interpolation, in a 1.5T cardiac scanner. (GE Medical Systems). Following myocardial and tag segmentation a four-dimensional B-spline based parametric motion field was computed for a volume of interest encompassing both ventr...