Detection of vein graft disease using high-resolution magnetic resonance angiography.

نویسندگان

  • Susan E Langerak
  • Hubert W Vliegen
  • Albert de Roos
  • Aeilko H Zwinderman
  • J Wouter Jukema
  • Patrik Kunz
  • Hildo J Lamb
  • Ernst E van Der Wall
چکیده

BACKGROUND The application of previous magnetic resonance (MR) angiography techniques has enabled noninvasive differentiation between patent and occluded coronary artery bypass grafts. However, the detection of graft stenosis remains difficult. The purpose of our study was to determine the accuracy of high-resolution navigator-gated 3-dimensional (3-D) MR angiography in detecting vein graft disease. Methods and Results- MR angiography was performed in addition to coronary angiography with quantitative coronary analysis in 56 vein grafts from 38 patients (mean age 66.6+/-9.3 years), who presented with recurrent chest pain after bypass surgery. Eighteen grafts showed a luminal stenosis >/=50%, 11 grafts a stenosis >/=70%, and 6 grafts were occluded. All MR angiograms were evaluated independently by 2 blinded observers, who scored the presence of graft occlusion and graft stenosis >/=50% and >/=70% with a confidence level of 1 to 10. MR image quality was judged as insufficient in 6 grafts and these were excluded. Receiver-operator characteristic analysis revealed an area under the curve of 0.89 and 0.89 for identifying graft occlusion, 0.81 and 0.87 for stenosis >/=50%, and 0.82 and 0.79 for stenosis >/=70% for the 2 observers, respectively. Interobserver agreement in assessing graft occlusion and stenosis >/=50% and >/=70% was 94% (kappa=0.74, r=0.81), 72% (kappa=0.40, r=0.66), and 82% (kappa=0.53, r=0.72), respectively. CONCLUSIONS High-resolution navigator-gated 3-D MR angiography allows not only good differentiation between patent and occluded vein grafts but also the assessment of vein graft disease with a fair diagnostic accuracy. This approach offers perspective as a noninvasive diagnostic tool for patients who present with recurrent chest pain after vein graft surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of subependymal veins using high-resolution magnetic resonance venography.

High-resolution magnetic resonance venography (HR-MRV) of intracranial subependymal veins using a two-dimensional Fourier-transform time-of-flight technique was performed on normal volunteers and clinical cases of cerebral disease. For the pulse sequence, fast-field-echo sequence was used with the following parameters: TR/TE/flip angle = 34 ms/12 ms/50 deg., 256 x 256 matrix, 1 mm effective sli...

متن کامل

Comprehensive assessment of a post-coronary bypass graft patient with cardiovascular magnetic resonance imaging and multi-detector computed tomography

Coronary bypass graft surgery (CABG) is a revascularization procedure which reduces myocardial ischemia and cardiovascular morbidity and mortality in selected patients; however, up to 40% of saphanous vein grafts may degenerate over 10 years. Although coronary angiography is the gold standard to detect graft patency and native vessel disease, sometimes it is difficult to locate the grafts resul...

متن کامل

High-resolution magnetic resonance coronary angiography of the entire heart using a new blood-pool agent, NC100150 injection: comparison with invasive x-ray angiography in pigs.

Recent developments of novel magnetic resonance intravascular contrast agents with low T1 in blood and a long intravascular half-life will rapidly position magnetic resonance coronary angiography (MRCA) at the threshold of clinical application. This article describes the use of one such intravascular contrast agent for noninvasive coronary angiography and comparison with routine invasive x-ray ...

متن کامل

Noninvasive detection of steno-occlusive disease of the supra-aortic arteries with three-dimensional contrast-enhanced magnetic resonance angiography: a prospective, intra-individual comparative analysis with digital subtraction angiography.

BACKGROUND AND PURPOSE Concomitant disease of the supra-aortic arteries can influence the outcome of surgical treatment of carotid artery stenosis. However, sensitivity and specificity data of noninvasive contrast-enhanced 3-dimensional (3D) magnetic resonance angiography (CE MRA) for the detection of steno-occlusive disease of the entire supra-aortic arteries including the circle of Willis rem...

متن کامل

Assessment of coronary artery bypass graft disease using cardiovascular magnetic resonance determination of flow reserve.

OBJECTIVES The purpose of this study was to assess the value of cardiovascular magnetic resonance (CMR)-determined graft flow and flow reserve in differentiating significant from non-significant vein graft disease. BACKGROUND In patients after coronary artery bypass grafting (CABG), non-invasive testing may be helpful in the detection of recurrent graft disease. METHODS Randomly selected pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 105 3  شماره 

صفحات  -

تاریخ انتشار 2002