Comparison of multiple non‐invasive methods of measuring cardiac output during pregnancy reveals marked heterogeneity in the magnitude of cardiac output change between women

نویسندگان

  • John W. Petersen
  • Jing Liu
  • Yueh‐Yun Chi
  • Melissa Lingis
  • R. Stan Williams
  • Alice Rhoton‐Vlasak
  • Mark S. Segal
  • Kirk P. Conrad
چکیده

Various non-invasive methods are available to measure cardiac output (CO) during pregnancy. We compared serial measures of CO using various methods to determine which provided the least variability. Ten patients with spontaneous pregnancy had estimation of CO at baseline prior to becoming pregnant and at the end of the first and third trimesters. Echocardiographic data were used to estimate CO using the Teichholz method, Simpson's biplane method, and the Doppler determined velocity time integral (VTI) method. In addition, a Bioz Dx device was used to estimate CO by impedance cardiography. CO estimated with the VTI method had the lowest beat-to-beat variability. CO estimated with the VTI method was higher than CO estimated with the 2D-Teichholz method and Simpson's method. The percent change in CO during pregnancy was similar for all echo methods (VTI, Teichholz, and Simpson's biplane). Baseline CO determined with impedance cardiography was higher than CO determined with the VTI method. However, change in CO during pregnancy was significantly lower when measured with impedance cardiography. There was marked heterogeneity in the degree of rise in CO during the first trimester (-3 to 55%). The wide variation in the gestational rise in CO was unexpected, and at least in part secondary to variable increase in heart rate. We recommend the use of the Doppler determined VTI method for the estimation of CO in pregnancy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

مقایسه تغییرات برون‌ده قلبی در 2 روش بیهوشی با هالوتان و پروپوفول در بیماران تحت عمل ترمیم روتاتورکاف در وضعیت نشسته با روش غیرتهاجمی

Maintenance of cardiac output in normal range to assure tissues and vital organ perfusion is one of the most important tasks of anesthetists. Hemodynamic and cardiac indices(e.g. cardiac output) change due to either anesthetic drugs or changes in body position during various surgical operations and they have also been important and notable problems. The goal of the present study was...

متن کامل

مانیتورینگ همودینامیک به روش غیر تهاجمی در بخش مراقبت های ویژه: مقاله مروری

Aim and background : Hemodynamic monitoring of critical patients in intensive units is the cornstone of care. It constitutes an extensive part of care and is helpful in determination of the causes and the response to treatment of hemodynamic instability. Aim of this review articale is to investigate of the Non invasive hemodynamic monitoring in critical care units. Materials and Methods:61 art...

متن کامل

Comparison of Fetal Echocardiography for Fetal Cardiac Structure in Women with Gestational Diabetes Mellitus and Normal Pregnancies

BackgroundIncreased metabolic rate of hyperglycemia in gestational diabetes causes macrosomia, which can also affect the fetal heart. The thickness of the walls of the heart and its function in women with gestational diabetes mellitus (GDM) can change over time before treatment. We aimed to evaluate fetal cardiac structure in terms of ventricular wall thickness and its function in women w...

متن کامل

Effect of Passive Leg Raising on Systemic Hemodynamics of Pregnant Women: A Dynamic Assessment of Maternal Cardiovascular Function at 22–24 Weeks of Gestation

OBJECTIVE To investigate functional hemodynamic response to passive leg raising in healthy pregnant women and compare it with non-pregnant controls. MATERIALS AND METHODS This was a prospective cross-sectional study with a case-control design. A total of 108 healthy pregnant women at 22-24 weeks of gestation and 54 non-pregnant women were included. Cardiac function and systemic hemodynamics w...