An investigation of image guidance dose for breast radiotherapy
نویسندگان
چکیده
Cone-beam computed tomography (CBCT) is used for external-beam radiation therapy setup and target localization. As with all medical applications of ionizing radiation, radiation exposure should be managed safely and optimized to achieve the necessary image quality using the lowest possible dose. The present study investigates doses from standard kilovoltage kV radiographic and CBCT imaging protocol, and proposes two novel reduced dose CBCT protocols for the setup of breast cancer patients undergoing external beam radiotherapy. The standard thorax kV and low-dose thorax CBCT protocols available on Varian's On-Board Imaging system was chosen as the reference technique for breast imaging. Two new CBCT protocols were created by modifying the low-dose thorax protocol, one with a reduced gantry rotation range ("Under breast" protocol) and the other with a reduced tube current-time product setting ("Low dose thorax 10ms" protocol). The absorbed doses to lungs, heart, breasts, and skin were measured using XRQA2 radiochromic film in an anthropomorphic female phantom. The absorbed doses to lungs, heart, and breasts were also calculated using the PCXMC Monte Carlo simulation software. The effective dose was calculated using the measured doses to the included organs and the ICRP 103 tissue weighting factors. The deviation between measured and simulated organ doses was between 3% and 24%. Reducing the protocol exposure time to half of its original value resulted in a reduction in the absorbed doses of the organs of 50%, while the reduced rotation range resulted in a dose reduction of at least 60%. Absorbed doses obtained from "Low dose thorax 10ms" protocol were higher than the doses from our departments orthogonal kV-kV imaging protocol. Doses acquired from "Under breast" protocol were comparable to the doses measured from the orthogonal kV-kV imaging protocol. The effective dose per fraction using the CBCT for standard low-dose thorax protocol was 5.00 ± 0.30 mSv; for the "Low dose thorax 10ms" protocol it was 2.44 ± 0.21 mSv; and for the "Under breast" protocol it was 1.23 ± 0.25 mSv when the image isocenter was positioned at the phantom center and 1.17 ± 0.30 mSv when the image isocenter was positioned in the middle of right breast. The effective dose per fraction using the orthogonal kV-kV protocol was 1.14 ± 0.16 mSv. The reduction of the scan exposure time or beam rotation range of the CBCT imaging significantly reduced the dose to the organs investigated. The doses from the "Under breast" protocol and orthogonal kV-kV imaging protocol were comparable. Simulated organ doses correlated well with measured doses. Effective doses from imaging techniques should be considered with the increase use of kV imaging protocols in order to support the use of IGRT.
منابع مشابه
Evaluation of deformable image registration in HDR gynecological brachytherapy
Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...
متن کاملنقش تکنولوژی در بهبود درمان سرطان
One major strategy, technology-driven improvement of treatment conformity in cancer treatment, including advanced image guidance, advanced charged particle therapy (CPT), and application of nanoparticles in hyperthermia, will enable further widening of the therapeutic window of cancer treatment in the era of precision medicine. The state of the art treatment in photon-therapy is advanced 3D...
متن کاملVerification of the Accuracy of the Delivered Dose in Pelvic and Breast Cancer Radiotherapy by in-vivo Semi-Conductor Dosimetry
Introduction: Delivering maximum dose to tumor and minimum dose to normal tissues is the most important goal in radiotherapy. According to ICRU, the maximum acceptable uncertainty in the delivered dose compared to the prescribed dose should be lower than 5%, and this is because of the relationship between absorbed dose, tumor control and normal tissue damage. Absorbed dose accuracy is investiga...
متن کاملDosimetric Study of Tissue Heterogeneity Correction for Breast Conformal Radiotherapy
Introduction: Heterogeneity correction is an important parameter in dose calculation for cancer patients where it may be cause inaccuracy in dose calculation as a result of different densities of patients. This study studied the impact of dose calculation of breast cancer patients with and without heterogeneity correction. Material and Methods: Twenty breast cancer patients were treated with Th...
متن کاملUniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.
Background & Objective: Radiotherapy has a very special significance in the treatment of cancer. Beam radiation therapy using photons and electrons produced by a linear accelerator is used extensively in the treatment of breast Cancer. In this article, In addition to providing a description of three techniques of radiotherapy in the treatment of breast cancer, has been Evaluating the effectiven...
متن کاملMeasurement of Thyroid Dose by TLD arising from Radiotherapy of Breast Cancer Patients from Supraclavicular Field
Background: Breast cancer is the most frequently diagnosed cancer and the leading global cause of cancer death among women worldwide. Radiotherapy plays a significant role in treatment of breast cancer and reduces locoregional recurrence and eventually improves survival. The treatment fields applied for breast cancer treatment include: tangential, axillary, supraclavicular and internal mammary ...