Assessment of QT-measurement accuracy using the 12-lead electrocardiogram derived from EASI leads.
نویسندگان
چکیده
The purpose of the present study is to assess QT-interval measurements from the EASI 12-lead electrocardiogram (ECG) as compared with the standard 12-lead ECG. The QT interval was automatically determined in simultaneously recorded standard and EASI 12-lead ECGs, using a validated wavelet-based delineator. The agreement between the 2 sets of measurements was quantified both on a lead-by-lead basis and a multilead basis with global definitions of QRS onset and T-wave end. The results show that the agreement between QT-interval measurements from the 2 lead systems is acceptable, with negligible mean differences and with correlation coefficients ranging from 0.91 to 0.98 depending on the lead studied. Although the SD shows a clear dependence on the selected lead (ranging from 9.2 to 26.4 milliseconds), differences are within the accepted tolerances for automatic delineation. In a few patients, large differences were found, mainly because of changes in morphology present in both lead systems. QT intervals measured by the multilead approach were considerably more stable than single-lead measurements and resulted in a much better agreement between the 2 lead systems (correlation coefficient, 0.98; QT difference, 1.1 +/- 9.8 milliseconds). Thus, the EASI 12-lead ECG may be used for reliable QT monitoring when the multilead delineation approach is adopted.
منابع مشابه
Deriving the 12-lead Electrocardiogram
This paper proposes a lead method and a processing means for monitoring the 12-lead electrocardiogram (ECG) with four standard leads. Leads I, II of the M-L leads and leads V1, V6 of the chest leads are used to record the ECG signals. The ECG waveforms of leads V2 through V5 are derived from the input signals using the least squares method based on the Frank torso model. This method makes it po...
متن کاملDeriving the 12-lead Ecg from Easi Electrodes via Nonlinear Regression
The standard 12-lead Electrocardiogram (ECG) is the basic clinical method of heart disease diagnosis. Measuring all 12 leads is often cumbersome and impractical especially on a long term monitoring. In 1988, Gordon Dower has introduced an EASI-lead ECG System, where only 5 electrodes are used. In order to gain all 12-lead ECG back from this EASI system, Dower’s equation was proposed then. Ever ...
متن کاملComparison of signal quality between EASI and Mason-Likar 12-lead electrocardiograms during physical activity.
BACKGROUND Myoelectric noise and baseline wander, artifacts that appear when patients move during electrocardiographic monitoring, can cause false alarms. This problem can be addressed by using a reduced lead set and placing electrodes on the anterior part of the torso only. The Mason-Likar modification of the standard 12-lead electrocardiogram and the EASI lead system are 2 alternative systems...
متن کاملDeriving the 12-lead Electrocardiogram From Four Standard Leads Based on the Frank Torso Model
Ab s t r a c t – This paper proposes a lead method and a processing means for monitoring the 12-lead electrocardiogram (ECG) with four standard leads. Leads I, II of the M-L leads and leads V1, V6 of the chest leads are used to record the ECG signals. The ECG waveforms of leads V2 through V5 are derived from the input signals using the least squares method based on the Frank torso model. This m...
متن کاملComparison of automatic QT measurement techniques in the normal 12 lead electrocardiogram.
OBJECTIVE To undertake a quantitative assessment of different automatic QT measurement techniques and investigate the influence of electrocardiogram filtering and algorithm parameters. DESIGN Four methods for identifying the end of the T wave were compared: (1) threshold crossing of the T wave (TH); (2) threshold crossing of the differential of the T wave (DTH); (3) intercept of an isoelectri...