A hospital-associated outbreak of Legionnaires' disease caused by Legionella pneumophila serogroup 1 is characterized by stable genetic fingerprinting but variable monoclonal antibody patterns.

نویسندگان

  • Sverker Bernander
  • Kerstin Jacobson
  • Jürgen Herbert Helbig
  • Paul Christian Lück
  • Monica Lundholm
چکیده

An outbreak of 18 pneumonia cases caused by Legionella pneumophila serogroup 1 occurred at a Swedish university hospital 1996 to 1999. Eight clinical isolates obtained by culture from the respiratory tract were compared to 20 environmental isolates from the hospital and to 21 epidemiologically unrelated isolates in Sweden, mostly from patients, by using pulsed-field gel electrophoresis (PFGE), amplified fragment length polymorphism analysis (AFLP), and monoclonal antibody (MAb) typing. All patients and most environmental isolates from the outbreak hospital belonged to the same genotypic cluster in both PFGE and AFLP. This genotype was distinctly different from other strains, including a cluster from a second hospital in a different part of the country. The MAb subtype of the outbreak clone was Knoxville except for three isolates that were Oxford. A variation in the MAb reactivity pattern was also found in a second genotypic cluster. These changes in the MAb reactivity pattern were due to the absence or presence of the lag-1 gene coding for an O-acetyltransferase that is responsible for expression of the lipopolysaccharide epitope recognized by MAb 3/1 of the Dresden Panel. In all MAb 3/1-positive strains, the lag-1 gene was present on a genetic element that was bordered by a direct repeat that showed a high degree of sequence homology. Due to this homology, the lag-1 gene region seemed to be an unstable element in the chromosome. MAb patterns are thus a valuable adjunct to genotyping methods in defining subgroups inside a genotypic cluster of L. pneumophila sg 1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of sensitivity of two serological tests for diagnosing pneumonia caused by Legionella pneumophila serogroup 1.

The sensitivity of an indirect immunofluorescence antibody test (IFAT) and a rapid microagglutination test (RMAT) for the diagnosis of Legionnaires' disease caused by Legionella pneumophila serogroup 1 was evaluated using serum specimens from 119 patients with bacteriologically confirmed infections. The sensitivity of both assays was found to be about 80%. In addition, antibody titres suggestiv...

متن کامل

Legionnaires' Disease Outbreak at a Long-Term Care Facility Caused by a Cooling Tower Using an Automated Disinfection System--Ohio, 2013.

On July 9, 2013, an outbreak of Legionnaires' disease (LD) was identified at Long-Term Care Facility A in central Ohio. This article describes the investigation of the outbreak and identification of the outbreak source, a cooling tower using an automated biocide delivery system. In total, 39 outbreak LD cases were identified; among these, six patients died. Water samples from a cooling tower we...

متن کامل

Legionnaires' disease on a cruise ship linked to the water supply system: clinical and public health implications.

The occurrence of legionnaires' disease has been described previously in passengers of cruise ships, but determination of the source has been rare. A 67-year-old, male cigarette smoker with heart disease contracted legionnaires' disease during a cruise in September 1995 and died 9 days after disembarking. Legionella pneumophila serogroup 1 was isolated from the patient's sputum and the ship's w...

متن کامل

Unusual Legionnaires' outbreak in cool, dry Western Canada: an investigation using genomic epidemiology

An outbreak of Legionnaires' disease occurred in an inner city district in Calgary, Canada. This outbreak spanned a 3-week period in November-December 2012, and a total of eight cases were identified. Four of these cases were critically ill requiring intensive care admission but there was no associated mortality. All cases tested positive for Legionella pneumophila serogroup 1 (LP1) by urinary ...

متن کامل

Two Legionnaires' disease cases associated with industrial waste water treatment plants: a case report

BACKGROUND Finnish and Swedish waste water systems used by the forest industry were found to be exceptionally heavily contaminated with legionellae in 2005. CASE PRESENTATION We report two cases of severe pneumonia in employees working at two separate mills in Finland in 2006. Legionella serological and urinary antigen tests were used to diagnose Legionnaires' disease in the symptomatic emplo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 41 6  شماره 

صفحات  -

تاریخ انتشار 2003