Calibration in three dimensions: optimizing a two-parameter calibration technique to extend the range of an immunoturbidimetric urinary albumin assay into antigen excess.

نویسنده

  • C Tillyer
چکیده

I describe a general technique, called "two-parameter calibration," which allows precise determination of analyte from non-monotonic calibration plots and the calibration of immunoturbidimetric assays in antigen excess. Using three-dimensional calibration plots and relative-sensitivity curves, two optimal parameters may be selected from a number of possible options by using criteria presented here. Choosing two different values of delta At1-t2, the change in absorbance from time t1 to t2--as the reaction parameters in an immunoturbidimetric assay for albumin, I have optimized the choice of time interval for two-parameter calibration and extended the working range of the assay by three- to fourfold. The albumin assay shows excellent agreement of observed and expected values (r = 0.996) and also with results of a routine kinetic dye-binding method used on diluted plasma samples (r = 0.970).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between immunoturbidimetry, size-exclusion chromatography, and LC-MS to quantify urinary albumin.

BACKGROUND The accurate and precise measurement of urinary albumin is critical, since even minor increases are diagnostically sensitive indicators of renal disease, cardiovascular events, and risk for death. To gain insights into potential measurement biases, we systematically compared urine albumin measurements performed by LC-MS, a clinically available immunoturbidimetric assay, and size-excl...

متن کامل

ارائه روش اصلح در اندازه گیری میزان پروتئین ادرار 24 ساعته

Introduction: In this study, we reviewuated and compared three routine methods for the measurement of urinary protein concentrations with a view to find a suitable method to prevent, diagnose and monitor renal disease under circumstances with limited resources. Materials and Methods: Two modifications of the Trichoroacetic acid (TCA) turbidimetric method read at 405 and 620 nm and the sulfosali...

متن کامل

Estimation and Calibration of Robot Link Parameters with Intelligent Techniques

Abstract: Using robot manipulators for high accuracy applications require precise value of the kinematics parameters. Since measurement of kinematics parameters are usually associated with errors and accurate measurement of them is an expensive task, automatic calibration of robot link parameters makes the task of kinematics parameters determination much easier. In this paper a simple and easy ...

متن کامل

On-Chip Immunoassay for Determination of Urinary Albumin

An immunoassay performed on a portable microfluidic device was evaluated for the determination of urinary albumin. An increase in absorbance at 500 nm resulting from immunoagglutination was monitored directly on the poly(dimethylsiloxane) (PDMS) microchip using a portable miniature fibre-optic spectrometer. A calibration curve was linear up to 10 mg L(-1) (r(2) = 0.993), with a detection limit ...

متن کامل

Comparison of the Obtained Results from Two Calibration Methods in MRI Brachytherapy Normoxic Polymer Gel Dosimetry

Introduction: Despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. In the current work, the feasibility of using a normoxic polymer gel dosimeter named MAGICA has been investigated for use in our clinical brachytherapy applic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 36 2  شماره 

صفحات  -

تاریخ انتشار 1990