Validation of a peak endocardial acceleration-based algorithm to optimize cardiac resynchronization: early clinical results

نویسندگان

  • Peter Paul Delnoy
  • Emanuela Marcelli
  • Henk Oudeluttikhuis
  • Deborah Nicastia
  • Fabrizio Renesto
  • Laura Cercenelli
  • Gianni Plicchi
چکیده

AIMS Cardiac resynchronization therapy (CRT) involves time-consuming procedures to achieve an optimal programming of the system, at implant as well as during follow-up, when remodelling occurs. A device equipped with an implantable sensor able to measure peak endocardial acceleration (PEA) has been recently developed to monitor cardiac function and to guide CRT programming. During scanning of the atrioventricular delay (AVD), PEA reflects both left ventricle (LV) contractility (LV dP/dt(max)) and transmitral flow. A new CRT optimization algorithm, based on recording of PEA (PEA(area) method) was developed, and compared with measurements of LV dP/dt(max), to identify an optimal CRT configuration. METHODS AND RESULTS We studied 15 patients in New York Heart Association classes II-IV and with a QRS duration >130 ms, who had undergone implantation of a biventricular (BiV) pulse generator connected to a right ventricular (RV) PEA sensor. At a mean of 39 +/- 15 days after implantation of the CRT system, the patients underwent cardiac catheterization. During single-chamber LV or during BiV stimulation, with initial RV or LV stimulation, and at settings of interventricular intervals between 0 and 40 ms, the AVD was scanned between 60 and 220 ms, while LV dP/dt(max) and PEA were measured. The area of PEA curve (PEA(area) method) was estimated as the average of PEA values measured during AVD scanning. A >or=10% increase in LV dP/dt(max) was observed in 12 of 15 patients (80%), who were classified as responders to CRT. In nine of 12 responders (75%), the optimal pacing configuration identified by the PEA(area) method was associated with the greatest LV dP/dt(max). CONCLUSION The concordance of the PEA(area) method with measurements of LV dP/dt(max) suggests that this new, operator-independent algorithm is a reliable means of CRT optimization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How should we optimize cardiac resynchronization therapy?

Optimization of cardiac resynchronization therapy is increasingly performed. Numerous methods have been proposed, many being echocardiographic. Both the technique and the timing of optimization are contentious. Whether acute haemodynamic benefits translate into long-term improvements in remodelling, symptoms, or prognosis is unknown. Recent guidelines from the American Society of Echocardiograp...

متن کامل

Left ventricular endocardial or triventricular pacing to optimize cardiac resynchronization therapy in a chronic canine model of ischemic heart failure.

Cardiac resynchronization therapy (CRT) is a proven treatment for heart failure but ~30% of patients appear to not benefit from the therapy. Left ventricular (LV) endocardial and multisite epicardial [triventricular (TriV)] pacing have been proposed as alternatives to traditional LV transvenous epicardial pacing, but no study has directly compared the hemodynamic effects of these approaches. Le...

متن کامل

ALternate Site Cardiac ResYNChronization (ALSYNC): a prospective and multicentre study of left ventricular endocardial pacing for cardiac resynchronization therapy.

AIMS The ALternate Site Cardiac ResYNChronization (ALSYNC) study evaluated the feasibility and safety of left ventricular endocardial pacing (LVEP) using a market-released pacing lead implanted via a single pectoral access by a novel atrial transseptal lead delivery system. METHODS AND RESULTS ALSYNC was a prospective clinical investigation with a minimum of 12-month follow-up in 18 centres o...

متن کامل

Retiming the failing heart: principles and current clinical status of cardiac resynchronization.

Left or biventricular (BiV) pacing, or cardiac resynchronization therapy, was proposed nearly 10 years ago as an adjunctive treatment for patients with advanced heart failure (HF) complicated by discoordinate contraction due to intraventricular conduction delay. Since then, both short-term and a growing number of long-term clinical trials have reported on the mechanisms and short- and mid-term ...

متن کامل

A Study of the Linear Electromagnetic Generator for Harvesting Electrical Energy from Initial Acceleration: Design, Optimization, and Experimental Validation

One of the important requirements in projectiles is to design a power supply for fuse consumption. In this study, an optimum design for the power supply, which includes a Miniaturized Inertia Generator (MIG), was introduced. The main objective of this research was to optimize the dimensions of the MIG with the aim of increasing energy. To achieve this, the design of experiment (DOE) was carried...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2008