A new venturi attachment for the Cape ventilator, to facilitate control of FIO2.

نویسندگان

  • R W Nickalls
  • P G Lawler
چکیده

The Cape ventilator (Penlon Ltd) still remains one of the most widely used ventilators in intensive therapy units (ITU). However, when low fractional inspired oxygen concentrations (F IO2 ) are prescribed, particularly when associated with low minute volumes (V̇ ), the required supplemental oxygen flow is small. Flows less than 2 litres/min are not uncommon. For example; an F IO2 of 0·35 and a V̇ of 8 litres/min requires an oxygen flow of only 1·4 litres/min. Such low flows cannot be delivered accurately with the commonly available Medishield wall flowmeters, which incidentally, are calibrated at only 350 kPa, and under-read when used at the normal hospital pipeline pressure of 400 kPa (BOC personal communication). Furthermore, when calculating the F IO2 from estimates of the tidal volume (V T ), frequency ( f ), and oxygen flow, the errors are such that only a very rough estimate can be made. F IO2 should always be measured directly (and preferably be monitored continuously) but oxygen analysers are still not available everywhere. We have devised a simple venturi attachment, easily made from components available in ITU, which facilitates prescription of the F IO2 . The attachment (Fig. 1) is made from an empty 1 litre Polyfusor infusion bottle (The Boots Company, PLC), the T-piece connector from a Magill rebreathing system, and the variable venturi supplied with the Hudson ‘multivent’ oxygen mask (Henleys Medical Supplies Ltd). The ‘giving-set’ end of the infusion bottle is cut off, leaving a hole the same diameter as the infusion bottle. A hole is also made in the other end to fit the T-piece connector. The venturi is fitted to the remaining female arm of the T-piece; the air entrainment apertures must be well clear of the infusion bottle. The attachment replaces the oxygen reservoir bag in the front port of the ventilator. The performances of five randomly selected venturis (each paired with a different Medishield flowmeter to maximise errors) were tested using a Cape ventilator set to deliver a minute volume much greater than would normally be used (V T 1500 ml, oxygen dilution; f 12·7 breaths/min). F IO2 was determined to the nearest 0·5% with a Servomex oxygen analyser for each venturi setting, both at the manufacturer’s recommended oxygen flow, and 2 litres/min less than this. The results are shown in Fig. 2. The slightly high F IO2 readings obtained using the ‘recommended’ oxygen flows are due to the added resistance offered to the venturi outflow at these higher flows by the T-piece connector and open ended reservoir, resulting in a decreased entrainment ratio at the venturi. We recommend therefore, that this attachment is used with an oxygen

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variability of inspired oxygen concentration with nasal cannulas.

BACKGROUND The likely values of inspired oxygen concentration (FIO2) of patients with chronic obstructive pulmonary disease breathing via nasal cannulas have not been assessed previously. METHODS Seven patients with chronic obstructive lung disease and seven healthy subjects were studied while breathing oxygen via nasal cannulas or fixed performance (Venturi) or uncontrolled (MC) oxygen masks...

متن کامل

Use of venturi entrainment to deliver nasal high flow oxygen.indd

Objective: To evaluate the use of an adjustable venturi device with standard wall oxygen supply to deliver nasal high flow oxygen. Design: We set up a circuit using a standard 15 L/ min oxygen rotameter connected to a wall outlet, 2 m standard oxygen tubing, an adjustable venturi device, humidification chamber and nasal high flow circuit and cannulae. Delivered FiO2 and total gas flow rates wer...

متن کامل

Associations between intraoperative ventilator settings during one-lung ventilation and postoperative pulmonary complications: a prospective observational study

BACKGROUND The interest in perioperative lung protective ventilation has been increasing. However, optimal management during one-lung ventilation (OLV) remains undetermined, which not only includes tidal volume (VT) and positive end-expiratory pressure (PEEP) but also inspired oxygen fraction (FIO2). We aimed to investigate current practice of intraoperative ventilation during OLV, and analyze ...

متن کامل

Numerical Analysis of Water and Air in Venturi Tube to Produce Micro-Bubbles

Two-phase flow regimes are affected by conduit position, alignment, geometry, flow direction, physical characteristics, and flow rate of each phase as well as the heat flux toward the boundaries. Due to the importance of two-phase flow, numerous regimes have been identified. The first step in studying micro-bubble formation inside a venturi tube is to recognize the type of flow regimes. In this...

متن کامل

بررسی کارایی اسکرابر ونچوری در جمع‌آوری گردوغبار هوابرد Fe2O3 در یک واحد آهن‌سازی

Background and aims: Steel industry plays an important role in air pollution and particulate emissions released to the environment. The Venturi scrubber is one of the most important scrubbers and components at local exhaust ventilation which has a lot of application to control of the contaminants emissions to the atmosphere in the steel industry. On the other hand, the efficiency of this equipm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anaesthesia

دوره 39 10  شماره 

صفحات  -

تاریخ انتشار 1984