Images in cardiovascular medicine. Myocardial ischemia diagnosed by dual-energy computed tomography: correlation with single-photon emission computed tomography.
نویسندگان
چکیده
For decades, dual-energy imaging has been used for tissue differentiation with several x-ray–based imaging modalities, exploiting the fact that the tissues in the human body show different absorption characteristics when penetrated with different x-ray spectra, spectra that are typically generated by different kV settings of the x-ray tube. Recently, dual-source computed tomography (CT) with 2 x-ray tubes and 2 detector arrays mounted in the same gantry has become available.1 After experience with earlier experimental prototypes, this dual-source CT for the first time enables the clinical acquisition of dual-energy CT studies simultaneously with a single scan. We used a dual-source CT scanner (Definition, Siemens, Forchheim, Germany) in dual-energy mode for performing coronary CT angiography in a 74-year–old woman with suspected coronary artery disease and prior abnormal nuclear rest/stress single-photon emission CT (SPECT). The CT scan was acquired with retrospective ECG-gating and the following scan parameters: 330-ms gantry rotation, pitch 0.2, and 32 2 0.6-mm collimation. One tube of the dual-source system was operated with 150 mAs/rot at 140 kV and the second tube with 165 mAs/rot at 80 kV. The scan was contrast medium–enhanced (70-mL Ultravist, 370-mg iodine/ mL; Bayer, Wayne, NJ), using our routine clinical protocol. From the dual-energy scan, 3 different image reconstructions with 0.75-mm section width and 0.4-mm increment were performed using the routine dual-energy CT reconstruction algorithm implemented on the scanner platform. The first set of transverse gray-scale images was aimed at optimizing spatial and contrast resolution by merging 70% of the 140-kV spectrum and 30% of the 80-kV spectrum, which was used for 3-dimensional volume rendering (Figure 1A) and morphological diagnosis based on automatically generated curved multiplanar reformations (Figure 1B and 1C) of the coronary artery tree. Another set was based only on the 80-kV x-ray spectrum (Figure 2A and 2D) and yet another only on the 140-kV x-ray spectrum (Figure 2B and 2E). The myocardial blood pool was analyzed by determining the iodine content within the myocardium on the basis of the unique x-ray absorption characteristics of this element at different kV levels. The resulting color-coded “iodine map” representing the myocardial blood pool was then superimposed onto gray-scale multiplanar reformats of the myocardium in shortFigure 1. Dual-energy CT scan reconstruction merging 70% of the 140-kV spectrum and 30% of the 80-kV spectrum shown as 3-dimensional volume rendering (A) and curved multiplanar reformations (B and C). Diffuse calcified atherosclerotic disease is seen throughout the vessel course with subtotal ostial stenosis (arrows) of the first diagonal branch, caused by extensive calcified and noncalcified plaque. D, Correlation with coronary catheter angiography.
منابع مشابه
Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کاملPrediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography
Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...
متن کاملUtilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملA study on differentiation of extra-cardiac activity by Slit Slat collimation in Single Photon Emission Computed Tomography
Introduction: Myocardial perfusion SPECTby 99mTc-Sestamibi and 99mTc-Tetrofosmin radiopharmaceuticals usually presents a false significant increase in the radiotracer uptake in the inferior myocardium due to the uptake in organs such as liver, bowel, stomach and biliary system. The present study evaluated a suitable Slit angle for differentiating extra-car...
متن کاملImage Optimization in Single Photon Emission Computed Tomography by Hardware Modifications with Monte Carlo Simulation
Introduction: In Single Photon Emission Computed Tomography (SPECT), the projection data used for image reconstruction are distorted by several factors, including attenuation and scattering of gamma rays, collimator structure, data acquisition method, organ motion, and washout of radiopharmaceuticals. All these make reconstruction of a quantitative SPECT image very difficult. Simulation of a SP...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 117 9 شماره
صفحات -
تاریخ انتشار 2008