A new approach to implant alignment and ligament balancing in total knee arthroplasty focussing on joint loads.

نویسندگان

  • Frauke Zimmermann
  • Christoph Schwenninger
  • Ulrich Nolten
  • Franz Peter Firmbach
  • Robert Elfring
  • Klaus Radermacher
چکیده

Preservation and recovery of the mechanical leg axis as well as good rotational alignment of the prosthesis components and well-balanced ligaments are essential for the longevity of total knee arthroplasty (TKA). In the framework of the OrthoMIT project, the genALIGN system, a new navigated implantation approach based on intra-operative force-torque measurements, has been developed. With this system, optical or magnetic position tracking as well as any fixation of invasive rigid bodies are no longer necessary. For the alignment of the femoral component along the mechanical axis, a sensor-integrated instrument measures the torques resulting from the deviation between the instrument's axis and the mechanical axis under manually applied axial compression load. When both axes are coaxial, the resulting torques equal zero, and the tool axis can be fixed with respect to the bone. For ligament balancing and rotational alignment of the femoral component, the genALIGN system comprises a sensor-integrated tibial trial inlay measuring the amplitude and application points of the forces transferred between femur and tibia. Hereby, the impact of ligament tensions on knee joint loads can be determined over the whole range of motion. First studies with the genALIGN system, including a comparison with an imageless navigation system, show the feasibility of the concept.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Soft tissue balancing in total knee arthroplasty.

A good outcome in total knee arthroplasty depends on many factors: joint alignment, range of motion, patellar tracking and ligament stability. A correct soft tissue balance keeps the joint aligned in flexion and extension, and therefore constitutes the most important factor for durability of the implant. Indeed, incorrect soft tissue balancing is the primary cause of early implant failure neces...

متن کامل

The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty

Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...

متن کامل

The Effect of Total Knee Arthroplasty on Hindfoot Alignment in Patients with Severe Genu Varum and Genu Valgum

Background: The maintenance of deformity in the ankle and hindfoot after correction of knee deformity following kneearthroplasty may cause abnormal tension in the knee and patient dissatisfaction. The aim of this study was to determinethe effect of knee arthroplasty on the hindfoot alignment in patients with severe genu varum and valgum.Methods: A total of 84 patients with pri...

متن کامل

A Computational Modeling Approach for Investigating Soft Tissue Balancing in Bicruciate Retaining Knee Arthroplasty

Bicruciate retaining knee arthroplasty, although has shown improved functions and patient satisfaction compared to other designs of total knee replacement, remains a technically demanding option for treating severe cases of arthritic knees. One of the main challenges in bicruciate retaining arthroplasty is proper balancing of the soft tissue during the surgery. In this study biomechanics of sof...

متن کامل

Ligament balancing in TKA: evaluation of a force-sensing device and the influence of patellar eversion and ligament release.

Ligament balancing in total knee arthroplasty may have an important influence on joint stability and prosthesis lifetime. In order to provide quantitative information and assistance during ligament balancing, a device that intraoperatively measures knee joint forces and moments was developed. Its performance and surgical advantages were evaluated on six cadaver specimens mounted on a knee joint...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedizinische Technik. Biomedical engineering

دوره 57 4  شماره 

صفحات  -

تاریخ انتشار 2012