Pyrogenic reactions in patients receiving conventional, high-efficiency, or high-flux hemodialysis treatments with bicarbonate dialysate containing high concentrations of bacteria and endotoxin.

نویسندگان

  • S M Gordon
  • C W Oettinger
  • L A Bland
  • J C Oliver
  • M J Arduino
  • S M Aguero
  • S K McAllister
  • M S Favero
  • W R Jarvis
چکیده

High-efficiency (HE) and high-flux (HF) hemodialysis are becoming increasingly popular methods for treating patients with chronic renal failure because they reduce the time required for dialysis treatment. HF and HE dialyzers require bicarbonate dialysate, often prepared from concentrates that can support bacterial growth with endotoxin production. There is a concern that endotoxins or bacteria may cross or interact at the membranes of these dialyzers, triggering the release of endogenous pyrogens (cytokines) by peripheral blood mononuclear cells to cause pyrogenic reactions (PR). To determine the incidence of PR and to examine the association between PR and levels of bacteria and endotoxin in dialysate, a cohort of patients receiving conventional, HE, or HF hemodialysis with bicarbonate dialysate and reprocessed dialyzers at three dialysis centers during a 12-month period was studied prospectively. All dialyzers underwent a test of membrane integrity before use. A total of 19 PR were identified among 18 patients in 26,877 hemodialysis treatments (0.7 PR/1,000 treatments). There was no significant difference in PR rates by treatment modality: conventional, 0.5 per 1,000 (7 PR/13,123 treatments) versus HE, 0.9 per 1,000 (9 PR/11,345) versus HF, 1.2 per 1,000 (3 PR/2,409) (P = 0.21; chi 2 test). Throughout the study period, bacterial counts for dialysate at each center significantly exceeded the Association for the Advancement of Medical Instrumentation's (AAMI) microbiologic standards for dialysate of less than 2,000 CFU/mL (mean, 19,000 CFU/mL), but water used in the reuse of dialyzers tested less than 200 CFU/mL.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective study of pyrogenic reactions in hemodialysis patients using bicarbonate dialysis fluids filtered to remove bacteria and endotoxin.

Pyrogenic reactions (PR) are a well-recognized complication of hemodialysis and have been associated with dialyzer reuse, high-flux dialysis, and bicarbonate dialysate. However, the roles of bacteria and endotoxin in dialysate for producing PR are not well defined. To determine the effect of removing most bacteria and endotoxin from the dialysate on the incidence of PR, a cohort of chronic hemo...

متن کامل

Pyrogen transfer across high- and low-flux hemodialysis membranes.

The extent to which bacterial products from contaminated dialysate enter a patient's blood depends upon the type and permeability of the hemodialysis membrane in use. This study was performed to assess the transfer of pyrogenic substances across both high- and low-flux membranes (DIAPES, Fresenius Polysulfone, Helixone, Polyamide S). All experiments were carried out in the saline-saline model. ...

متن کامل

The Effect of the Type of Hemodialysis Buffer on the QTc Interval in Patients on Chronic Hemodialysis

Background: Identifying the sources of variation in QTc measurements is important for preventing arrhythmias during and after hemodialysis. The present study was designed to determine the correlation between the type of hemodialysis buffer and the changes in QTc interval in patients on chronic hemodialysis. Methods: Fifty-nine patients on chronic hemodialysis who referred in winter 2007 to hemo...

متن کامل

Normalization of uremic acidosis in hemodialysis patients with a high bicarbonate dialysate.

Uremic acidosis accompanies chronic renal failure in hemodialysis patients because of a retention of nonvolatile acids. Standard bicarbonate (39 mEq/L) and acetate (38 mEq/L) dialysates do not completely correct the acidosis. The acid-base and biochemical effect of a high-bicarbonate (42 mEq/L) dialysate was evaluated in 38 patients during high-efficiency and high-flux dialysis over 12 wk. All ...

متن کامل

اثر نوع محلول بافر همودیالیز در کنترل فشارخون و کفایت دیالیز بیماران همودیالیزی مزمن

Background: The effect of kind of dialysis solution on the control of blood pressure and adequacy and efficacy of hemodialysis is a most debated and controversial issue. Methods: Twenty six chronic hemodialized patients in Ghaem hemodialysis center, Mashhad, Iran, in winter of the year 2004, enrolled this study for one month. The patients were dialyzed with bicarbonate buffer and were dialy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society of Nephrology : JASN

دوره 2 9  شماره 

صفحات  -

تاریخ انتشار 1992