Management of isolated thyroid swellings: a prospective six year study of fine needle aspiration cytology in diagnosis.
نویسندگان
چکیده
OBJECTIVE To audit the accuracy and impact on the frequency of operation of fine needle aspiration cytology of isolated thyroid swellings. DESIGN Prospective analysis over six years of cytological predictions compared with histological findings. SETTING Thyroid clinic serving the Grampian region. PATIENTS 395 Consecutive patients presenting with an isolated thyroid swelling, 307 of whom underwent surgical excision. Analysis was confined to a subgroup of 283 patients with satisfactory aspirates who were operated on. RESULTS The positive predictive value of aspiration cytology for detecting malignant disease was 100% and the sensitivity 83%. The sensitivity for the detection of neoplasia (frank malignancy together with follicular adenomas) was 76%. The specificity was 58% and the overall accuracy 69%. Recalculation of data in previous papers with strict criteria showed the accuracy of aspiration cytology to be variable and lower than is widely accepted. Since the introduction of aspiration cytology 21% fewer operations for isolated thyroid swellings have been performed. CONCLUSIONS As a basis of selection for surgical excision of isolated thyroid swellings according to prediction of neoplasia fine needle aspiration cytology is less reliable than is widely accepted. It is an adjunct to management rather than a definitive test, and negative cytological results do not exclude neoplastic disease. Further study should take account of the implications of repeated clinic attendances for review and aspiration as these may culminate in delayed surgical treatment.
منابع مشابه
Diagnostic Accuracy of Frozen Section in Comparison With Fine Needle Aspiration Cytology in Thyroid Lesions – A Prospective Study
Background and Objectives: Thyroid gland because of its superficial location is amenable to direct physical examination. Clinical assessment of thyroid lesions by means of physical examination, thyroid scans and ultrasonography is not completely reliable. Fine needle aspiration cytology (FNAC) is the most cost-effective, safe and an initial diagnostic test in the pre-operative evaluation of thy...
متن کاملRole of Fine Needle Aspiration Cytology in Diagnosis of Solitary Thyroid Nodules
Introduction: This study was conducted at the Department of ear, nose, throat, head and neck surgery, Post Graduate Medical Institute Lady Reading Hospital Peshawar. The duration of the study was one year from June 17, 2009 to June 16, 2010. The sample size was 82 patients with solitary thyroid nodule, fulfilling the inclusion criteria. After taking detailed history, thorough examination, rele...
متن کاملDiagnostic Fine Needle Aspiration in a Case of Riedel’s Thyroiditis
In Riedel’s thyroiditis, a rare chronic inflammatory disease of thyroid gland, fine needle aspiration is usually non-diagnostic because most often only follicular cells are obtained and not the fibrous material characteristic of this type of thyroiditis. Therefore the diagnosis is often only established by histopathologic study of the surgically obtained biopsy. The illustrated case is a 46-yea...
متن کاملFine needle aspiration cytology in isolated thyroid swellings: a prospective two year evaluation.
During 1 September 1981 to August 1982 aspiration cytology was carried out in all isolated thyroid swellings referred to the Aberdeen Thyroid Clinic: cytological findings were not disclosed, did not influence management, and were compared retrospectively with the histological diagnosis. In a total of 70 swellings sensitivity for the detection of neoplasia was 86% and overall accuracy 92%; the p...
متن کاملFine Needle Aspiration Cytology versus Fine Needle Capillary Sampling in Cytological Diagnosis of Thyroid Lesions
Background and Objectives: Fine needle aspiration cytology (FNAC) is an established out- patient procedure used in primary diagnosis of palpable thyroid lesions. A modified technique fine needle capillary sampling (FNCS) obviates the need of suction, is less painful, patient friendly and reported to overcome the problem of inadequate and bloody specimens. The aim of our study was to compare the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMJ
دوره 301 6747 شماره
صفحات -
تاریخ انتشار 1990