Position Sensing from Charge Dispersion in Micro-Pattern Gas Detectors with a Resistive Anode
نویسنده
چکیده
Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number of electronics channels for certain potential micro-detector applications such as the Time Projection Chamber. We describe below a new technique to achieve good spatial resolution without increasing the electronics channel count in a modified micro-detector outfitted with a high surface resistivity anode readout structure. The concept and preliminary measurements of spatial resolution from charge dispersion in a modified GEM detector with a resistive anode are described below.
منابع مشابه
Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode
The TPC for the International Linear Collider (ILC) will need to measure about 200 track points with a transverse resolution close to 100 μm. The resolution goal is beyond the capability of the conventional proportional wire/cathode pad TPC and Micro-Pattern Gas Detectors (MPGD) are being developed to meet the challenge. The standard MPGD readout techniques will, however, have difficulty in ach...
متن کامل2 00 6 Spatial resolution of a GEM readout TPC using the charge dispersion signal
A large volume Time Projection Chamber (TPC) is being considered for the central charged particle tracker for the detector for the proposed International Linear Col-lider (ILC). To meet the ILC-TPC spatial resolution challenge of ∼ 100 µm with a manageable number of readout pads and channels of electronics, Micro Pattern Gas Detectors (MPGD) are being developed which could use pads comparable i...
متن کاملCross Strip Anode Imaging Readouts for Microchannel Plate Detectors
We have developed a novel microchannel plate readout scheme, the cross strip anode. The cross strip anode has a coarse (0.5mm) multilayer metal and ceramic cross strip pattern that encodes event positions by direct sensing of the charge on each strip and subsequent determination of the charge cloud centroid for each event. Event position encoding is accomplished with chip level preamplifiers on...
متن کاملTHGEM-based detectors for sampling elements in DHCAL: laboratory and beam evaluation
We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm 2 prototype detector with 1 cm 2 readout pads. The detector is comprised of singleor double-THGEM multipliers coupl...
متن کاملCharacterization and Calibration of Large Area Resistive Strip Micromegas Detectors
Resistive strip Micromegas detectors have been tested extensively as small detectors of about 10 x 10 cm2 in size and they work reliably at high rates of 100 kHz/cm2 and above. Tracking resolution well below 100μm has been observed for 100 GeV muons and pions. Micromegas detectors are meanwhile proposed as large area muon precision trackers of 2-3 m2 in size. To investigate possible differences...
متن کامل