The physics of phaco: a review.

نویسندگان

  • Mark Packer
  • William J Fishkind
  • I Howard Fine
  • Barry S Seibel
  • Richard S Hoffman
چکیده

Despite its unparalleled success in the field of surgery, the precise mechanism of ultrasonic phacoemulsification cataract extraction remains controversial. We review the relevant peer-reviewed literature on the subject of power generation and tip-tissue interactions to clarify the current status of our knowledge. We conclude that phacoemulsification most likely operates by a combination of mechanisms, including direct action of the vibrating tip against tissue and indirect cavitational effects. Surgeons will benefit from understanding the physical principles underlying phacoemulsification because they will be better able to evaluate the performance of various parameters and different machine settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

IOP Maintenance in SLT-treated Eyes following Subsequent Phacoemulsification and IOL

To assess whether the intraocular pressure (IOP) in selective laser trabeculoplasty (SLT)-treated eyes is maintained following subsequent phacoemulsification and lens implant (phaco + IOL). Retrospective single center review of 45 eyes of 35 patients who had open angle glaucoma (OAG), successfully treated by SLT by the same surgeon (EA), and then had routine phaco + IOL by same surgeon (EA). Th...

متن کامل

Comparison between phaco-deep sclerectomy converted into phaco-trabeculectomy and uneventful phaco-deep sclerectomy.

PURPOSE To evaluate and compare the results and complications of eyes that underwent a phaco-deep sclerectomy (DS) converted into phaco-trabeculectomy due to an intraoperative macroperforation with eyes undergoing uneventful phaco-DS. METHODS The authors reviewed 106 eyes having a planned phaco-DS; 10 of them (9.4%) had to be converted into phaco-trabeculectomy because of a large perforation ...

متن کامل

Corneal Problems during and after Phacoemulsification by Beginner Phacoemulsification Surgeon

Objective: To determine the corneal problems faced during and after phacoemulsification (phaco) as a beginner of phaco surgeries Methodology: Corneal problems in 100 cases of phaco were retrospectively analysed. Those cases with nuclei +3 / above and those who were operated in camps were excluded. Phaco-chop technique was used in 80% of cases. Average duration of surgery was 20 minutes Results:...

متن کامل

Surgical treatment for primary angle closure-glaucoma: a Meta analysis.

AIM To evaluate the efficacy and safety of trabeculectomy, phacotrabeculectomy plus intraocular lens implantation(phacotrab+IOL group) and phacoemulsification with IOL(phaco+IOL) in primary angle-closure glaucoma(PACG). METHODS It was a systematic review and meta-analysis, randomized controlled trials(RCT) and clinical controlled trials(CCT) were collected through electronic searches of the C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 31 2  شماره 

صفحات  -

تاریخ انتشار 2005