No increased risk of early revision during the implementation phase of new cup designs
نویسندگان
چکیده
Background and purpose - In Sweden, less than 5% of patients who undergo total hip arthroplasty (THA) have revision. Younger patients have an increased risk of revision. New prosthetic designs are being introduced in order to improve outcomes further. We investigated whether the introductory phase of new cup designs would increase the revision rate. Patients and methods - All THAs and first-time cup revisions performed from 1993 through 2011 were identified in the Swedish Hip Arthroplasty Register. The 15 types of cups used in more than 500 operations and inserted in more than 50 cases in each hospital (n = 52,903) were selected. All cups were given an order number, based on the order in which the cup had been inserted at each hospital. The influence of order number on the risk of revision was analyzed in a regression model, which was adjusted for potentially confounding demographic and surgical data. Revision within 2 years for all reasons (n = 940) was used as primary endpoint. Changes in the risk of revision based on the order number were analyzed using a spline. Results - The order number of the cup had no influence on the risk of early revision (p ≥ 0.7). Categorizing the order number using cutoff values obtained from the splines did not result in any statistically significant changes in risk of revision (p ≥ 0.2). Interpretation - We did not find any increased risk of early revision during the implementation phase of new cup designs. This finding is unexpected, and partly conflicts with data from other registries. The structured and stepwise introduction of new prosthesis designs, facilitated by the annual feedback from the Swedish Hip Arthroplasty Register, may partly explain this discrepancy.
منابع مشابه
Hip prosthesis introduction and early revision risk
BACKGROUND AND PURPOSE Little is known about the effect of the learning curve for different types of total hip arthroplasties (THAs). We investigated the prostheses survival of THAs just after the implementation of a model new to the hospital, and compared these results with the results of THAs done when more than 100 implantations had been undertaken. In addition, we investigated whether diffe...
متن کاملShort-term survival of the trabecular metal cup is similar to that of standard cups used in acetabular revision surgery
BACKGROUND AND PURPOSE The use of trabecular metal (TM) cups in revision surgery has increased worldwide during the last decade. Since the introduction of the TM cup in Sweden in 2006, this design has gradually replaced other uncemented designs used in Sweden. According to data from the Swedish Hip Arthroplasty Register (SHAR) in 2012, one-third of all uncemented first-time cup revisions were p...
متن کاملImplementation Procedures for the Risk in Early Design (RED) Method
Risk assessments performed at the conceptual design phase of a product may offer the greatest opportunity to increase product safety and reliability at the least cost. This is an especially difficult proposition, however, as often the product has not assumed a physical form at this early design stage. This paper introduces the Risk in Early Design (RED) method, a method for performing risk asse...
متن کاملOutcome in design-specific comparisons between highly crosslinked and conventional polyethylene in total hip arthroplasty
Background and purpose - Most registry studies regarding highly crosslinked polyethylene (XLPE) have focused on the overall revision risk. We compared the risk of cup and/or liner revision for specific cup and liner designs made of either XLPE or conventional polyethylene (CPE), regarding revision for any reason and revision due to aseptic loosening and/or osteolysis. Patients and methods - Usi...
متن کاملEffects of hydroxyapatite coating of cups used in hip revision arthroplasty
BACKGROUND AND PURPOSE Coating of acetabular revision implants with hydroxyapatite (HA) has been proposed to improve ingrowth and stability. We investigated whether HA coating of revision cups can reduce the risk of any subsequent re-revision. METHODS We studied uncemented cups either with or without HA coating that were used at a primary acetabular revision and registered in the Swedish Hip ...
متن کامل