Central corneal thickness and thickness of the lamina cribrosa in human eyes.
نویسندگان
چکیده
PURPOSE Since central corneal thickness may inversely influence the amount and rate of progression of glaucomatous optic nerve damage and because lamina cribrosa thickness may be of importance in susceptibility to glaucoma, it was the purpose of the present study to evaluate whether central corneal thickness is related to lamina cribrosa thickness. METHODS The histomorphometric study included 111 enucleated nonglaucomatous eyes of 111 white subjects. On anterior-posterior histologic sections through the pupil and the central optic disc region, the thickness of the cornea, lamina cribrosa, and peripapillary sclera and the shortest distance between the intraocular space and the cerebrospinal fluid space were measured. Axial length ranged between 20 and 32 mm. RESULTS Mean central corneal thickness (mean +/- SD: 616.6 +/- 108.3 microm) and mean central lamina cribrosa thickness (378.1 +/- 117.8 microm) were statistically independent of each other (P = 0.15; correlation coefficient, r = 0.14). In a similar manner, lamina cribrosa thickness at the optic disc border was statistically independent of central corneal thickness (P = 0.51; r = 0.06) and peripheral corneal thickness (P = 0.34; r = 0.09). In a parallel way, peripapillary scleral thickness (P = 0.84) and the shortest distance between the prelaminar space and cerebrospinal fluid space (P = 0.10) were statistically independent of central corneal thickness. CONCLUSIONS In nonglaucomatous human globes, central corneal thickness may not correlate significantly with lamina cribrosa thickness, peripapillary scleral thickness, and shortest distance between intraocular space and cerebrospinal fluid space. Histologic artifact and sectioning methods could partially account for the lack of an association. The study results may suggest clinically that an assumed relationship between central corneal thickness and susceptibility to glaucoma cannot be explained by an anatomic correspondence between corneal thickness and histomorphometry of the optic nerve head.
منابع مشابه
Quantitative analysis of neural tissues around the optic disc after panretinal photocoagulation in patients with diabetic retinopathy
In this retrospective cross-sectional study, we quantitatively analyzed the tomographic features in the neural tissues around the optic disc in patients with diabetic retinopathy with and without panretinal photocoagulation. We analyzed 206 eyes, comprising 33 normal eyes in subjects without diabetes (group I), 30 eyes without diabetic retinopathy (group II), 66 eyes with non-proliferative diab...
متن کاملComparison of Central Corneal Thickness Measured through Pentacam, OCTCasia2, and Orbscan IIz in Normal Individuals
Purpose: To compare the central corneal thickness measured through Pentacam, OCTCasia2, and Orbscan IIz in normal individuals. Methods: In this cross sectional comparative study, the researcher investigated the eyes of 70 normal candidates (140 eyes) with the mean age of 31.42 ± 7.70, referring to Dr. Sedaghat eye clinic for refractive surgery. For each person, Central Corneal Thickness (CCT) w...
متن کاملScleral Thickness in Human Eyes
PURPOSE To obtain information about scleral thickness in different ocular regions and its associations. METHODS The histomorphometric study included 238 human globes which had been enucleated because of choroidal melanomas or due to secondary angle-closure glaucoma. Using light microscopy, anterior-posterior pupil-optic nerve sections were measured. RESULTS In the non-axially elongated grou...
متن کاملThree-dimensional imaging of lamina cribrosa defects in glaucoma using swept-source optical coherence tomography.
PURPOSE To visualize lamina cribrosa defects using three-dimensional (3D) swept-source optical coherence tomography (SS-OCT), and to determine the factors associated with this feature. METHODS All subjects were examined using an SS-OCT prototype system, which uses a tunable laser as a light source, operated at 100,000 Hz A-scan repetition rate in the 1050-nm wavelength. A 3D raster scan proto...
متن کاملOcular Hypertension: General Characteristics and Estimated Cerebrospinal Fluid Pressure. The Beijing Eye Study 2011
PURPOSE To examine characteristics of ocular hypertensive subjects and potential associations with estimated cerebrospinal fluid pressure (estCSFP). METHODS The population-based Beijing Eye Study 2011 included 3468 individuals with a mean age of 64.6±9.8 years. Ocular hypertension was defined as intraocular pressure (IOP) >21 mmHg, normal optic nerve head appearance and normal retinal nerve f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 46 4 شماره
صفحات -
تاریخ انتشار 2005