Triflusal versus oral anticoagulation for primary prevention of thromboembolism after bioprosthetic valve replacement (trac): prospective, randomized, co-operative trial.

نویسندگان

  • José Ignacio Aramendi
  • Carlos-Alberto Mestres
  • Juan Martinez-León
  • Vicente Campos
  • Genís Muñoz
  • Carlos Navas
چکیده

OBJECTIVE Antiplatelet agents are used for prevention of thromboembolism in surgical patients and in patients with chronic atrial fibrillation. Up to date, however, results of randomized studies comparing antiplatelet agents and oral anticoagulation have not been reported. The aim of this study was to compare the efficacy and safety of triflusal (an antiplatelet agent) versus acenocoumarol for primary prevention of thromboembolism in the early postoperative period after implantation of a bioprosthesis. METHODS In this prospective, multicentric, randomized, open pilot trial, patients were assigned to treatment with triflusal (600mg/d) or acenocoumarol (target INR 2.0-3.0). Study medication was started 24-48h after valve replacement with a bioprosthesis, and continued for 3 months. Four follow-up visits were scheduled: baseline, and at 1, 3 and 6 months thereafter. The primary end-point was a composite of the rate of thromboembolism, severe hemorrhage and valve-related mortality. RESULTS A total of 193 patients were included (97 received triflusal and 96 acenocoumarol), with a mean age of 72.5 years. Half were men. Aortic valve replacement was performed in 181 patients (93.8%), mitral valve replacement in 10 patients (5.2%) and double valve replacement in 2 (1.0%). Hospital mortality was 11 (5.7%). Primary outcome was recorded in 9 patients with triflusal (9.4%) and in 10 patients with acenocoumarol (11%). There were nine episodes (4.7%) of thromboembolism, six in the triflusal group and three in the acenocoumarol group, and three episodes of permanent neurological deficits, one in the triflusal group and two in the acenocoumarol group. Severe hemorrhage: nine episodes, six in the acenocoumarol group and three in the triflusal group. None of the observed differences in efficacy were statistically significant. Regarding safety, three patients in triflusal group reported at least one hemorrhage, compared to 10 in acenocoumarol group (P=0.048). CONCLUSIONS There were no significant differences in efficacy between both groups, however, triflusal showed a significantly lower incidence of bleeding episodes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: final report of the Veterans Affairs randomized trial.

OBJECTIVES The goal of this study was to compare long-term survival and valve-related complications between bioprosthetic and mechanical heart valves. BACKGROUND Different heart valves may have different patient outcomes. METHODS Five hundred seventy-five patients undergoing single aortic valve replacement (AVR) or mitral valve replacement (MVR) at 13 VA medical centers were randomized to r...

متن کامل

Warfarin versus dipyridamole-aspirin and pentoxifylline-aspirin for the prevention of prosthetic heart valve thromboembolism: a prospective randomized clinical trial.

In a prospective, randomized, parallel study, two regimens of platelet-suppressant therapy (PST)--dipyridamole-aspirin and pentoxifylline-aspirin--were compared with standard oral anticoagulation with warfarin in the prevention of prosthetic heart valve thromboembolism. In the entire group of 254 patients followed for 395.6 patient-years, the thromboembolic rate was significantly less in the wa...

متن کامل

Prosthetic Valve Dysfunction

Approximately 85,000 valve substitutes are implanted in the United States and 275,000 worldwide each year, of which approximately half are mechanical valves and half are bioprosthetic valves. Despite the marked improvements in prosthetic valve design and surgical procedures over the past decades, valve replacement is not a panacea for the patient. Instead, native valve disease is traded for pro...

متن کامل

INR self-management permits lower anticoagulation levels after mechanical heart valve replacement.

BACKGROUND The Early Self Controlled Anticoagulation Trial (ESCAT I) showed that anticoagulation self-management after mechanical heart valve replacement decreased complication rates by maintaining INR levels closer to the target range than International Normalized Ratio (INR) home doctor management. The therapeutic range for the INR in that study was between 2.5 and 4.5 for all positions of pr...

متن کامل

High risk of thromboemboli early after bioprosthetic cardiac valve replacement.

OBJECTIVES We studied the rate of thromboembolism in patients undergoing bioprosthetic replacement of the aortic or mitral valve, or both, at serial intervals after operation and the effects of anticoagulant or antiplatelet treatment and risk factors. BACKGROUND Thromboembolism appears to occur early after operation, but the incidence, timing and risk factors for thromboembolism and the role,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 27 5  شماره 

صفحات  -

تاریخ انتشار 2005