Traditional elastic ligatures versus slide ligation system. A morphological evaluation.

نویسندگان

  • R Condò
  • A Casaglia
  • E Armellin
  • S G Condò
  • L Cerroni
چکیده

OBJECTIVE Elastomeric materials play an important role in the orthodontic practice, including the retraction force to move teeth into extraction sites, closing diastemas, selective shifting of the midline and generalized space closure. Frictional resistance and ligating strength of archwire-bracket-ligature complex occurs during utilization of elastomeric and metallic ligatures when orthodontic forces are applicated. The aim of this study was to analyze elastic deformation of three types of elastomeric ligatures, after clinical use. MATERIAL AND METHODS ELASTOMERIC LIGATURES: ring-shape, transparent, latex ligatures (Leone® S.p.A.), ring-shape, grey, polyurethane ligatures (Micerium® S.p.A.) and grey, polyurethane, Slide low-friction ligatures (Leone® S.p.A.). A total of 9 orthodontic patients undergoing fixed orthodontic therapy were selected. Three specimens were applied, one for each types of ligature, inside the oral cavity of each subject. Samples were kept in the oral cavity for 28 days, ligating 0.16 X 0.22 inches stainless steel archwires to stainless steel premolars brackets (Leone® S.p.A., Sesto Fiorentino, FI, Italy) for Bidimensional technique. After the pre-established time, the systems of ligature were removed and washed. Control group consisted of 9 unused specimens of each ligation type. Each elastomeric ligature was observed under the scanning electron microscope (SEM) to determine variations in size. The archwire-bracket-ligature complex was also analyzed. RESULTS Transparent O-ring ligatures showed significant volumetric and structural changes. The external rounded shape was rather maintained, while the internal shape tended to appear square. Both external and internal diameter significantly increased (p<0.005 and p<0.0001 respectively) while the thickness decreased ( p<0,005) when analyzed with t-test. Polyurethane ring-shape ligatures retained the initial ring design. Both external and internal diameter increased (p<0.0001), while the thickness remained almost unchanged. The internal border was more squared, and showed jagged edges with continuous and irregular extroversions. Grey, polyurethane Slide low-friction ligatures showed a reduced dimensional change. There was a slight increase in two dimensions, length and width, (14-16%) (p<0.05 and p<0.001) while there was a not significant decrease in thickness (10%). CONCLUSION From SEM analysis of ligature morphology it emerges that latex and polyurethane O-ring ligatures endure significant volumetric and structural changes, after clinical use, index of a greater degree of friction and early loss in functionality. Grey, polyurethane Slide low-friction ligatures presented limited variation in size after clinical use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plaque retention on elastomeric ligatures. An in vivo study.

UNLABELLED Fixed orthodontic appliances make it difficult to maintain the oral hygiene, resulting in plaque accumulation. Retention of bacterial plaque, represents a risk for white spot lesions and development of periodontal disease. AIM Purpose of this study was to determine in vivo the retention of plaque on three different elastic ligatures, in comparison with stainless steel ligature, to ...

متن کامل

Frictional Properties of Self-Ligating Brackets and Low-Friction Ligatures

Problem statement: To evaluate the frictional forces generated by five different orthodontic brackets when used in combination with stainless steel and NiTi archwires in dry conditions at physiological temperature. Approach: Five different types of maxillary canine brackets (Damon 3 MX, Step, Quick, Sprint, Mini Mono) with a slot size 0.022 inch were coupled with 0.016” and 0.019”×0.025” stainl...

متن کامل

The Effect of Various Ligation Methods on Friction in Sliding Mechanics

Aim: To evaluate the effect of ligation method on friction and the efficacy of the new slick elastomeric modules (TP Orthodontics, USA) and slide elastomeric modules (Leone Orthodontics, Italy) which claim to reduce friction at the module/wire interface. Materials and methods: Slick and slide modules were compared with regular modules, modules tied in figure of eight fashion, tight stainless st...

متن کامل

Orthodontic forces released by low-friction versus conventional systems during alignment of apically or buccally malposed teeth.

The aim of the present study was to analyse the forces released by passive stainless steel self-ligating brackets (SLBs) and by a non-conventional elastomeric ligature-bracket system on conventional brackets ([slide ligatures on conventional brackets (SLCB)]) when compared with conventional elastomeric ligatures on conventional brackets (CLCB) during the alignment of apically or buccally malpos...

متن کامل

Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study

OBJECTIVE The aim of this article was to assess how intraoral biodegradation influenced the surface characteristics and friction levels of metallic brackets used during 12 and 24 months of orthodontic treatment and also to compare the static friction generated in these brackets with four different methods of the ligation of orthodontic wires. MATERIAL AND METHODS Seventy premolar brackets as ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • ORAL & implantology

دوره 6 1  شماره 

صفحات  -

تاریخ انتشار 2013