Technical evaluation of a new immunoradiometric and a new immunoluminometric assay for thyroglobulin.

نویسندگان

  • Nils G Morgenthaler
  • Juergen Froehlich
  • Johann Rendl
  • Marita Willnich
  • Christine Alonso
  • Andreas Bergmann
  • Christoph Reiners
چکیده

BACKGROUND After removal of differentiated thyroid carcinoma (DTC), serum thyroglobulin (Tg) can indicate persistent or recurrent disease. We describe two novel two-step assays designed to measure low Tg concentrations. METHODS We evaluated prototypes of the new IRMA, DYNOtest Tg-pluS, and the new immunoluminometric assay (ILMA), LUMItest) Tg-pluS. In the first step, a high-salt incubation buffer leads to dissociation of Tg-Tg antibody complexes in serum and is intended to reduce nonspecific interference and interference of potential Tg autoantibodies in the system. We studied recovery of human Tg (from thyroid glands) added to horse serum. We also studied 58 patients with DTC in whom Tg values under thyroid-stimulating hormone (TSH) suppression and TSH stimulation (without thyroxine) were available. RESULTS The detection limits were 0.04 microg/L Tg for the IRMA and 0.02 microg/L for the ILMA. Intraassay imprecision (CV) was <10% over the range of the calibration curve in both assays. The day-to-day CV was <20% at 0.2 microg/L for the IRMA and at 0.06 microg/L for the ILMA. No high-dose hook effect was seen with up to 200 000 microg/L added Tg or in dilutions of 12 patient sera with Tg values of 307-38 880 microg/L. Mean recovery of 50 microg Tg/L was 96% in those patients. Among 77 samples with Tg antibody values of 65.2-8150 kilounits/L, recovery by the IRMA was disturbed in 7 cases (9%) and by the ILMA in 9 cases (12%). Tg increased as measured in both assays in 50 of 58 patients after thyroxine withdrawal. CONCLUSIONS The new assays have improved precision for Tg <1 microg/L, and even low measured Tg concentrations respond physiologically to thyroxine withdrawal. The assays are free of a high-dose hook effect up to a Tg concentration of at least 38 000 microg/L and may further reduce Tg antibody interference.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonisotopic "sandwich" immunoassay of thyroglobulin in serum by the biotin-streptavidin technique: evaluation and comparison with an immunoradiometric assay.

In this sequential assay, the thyroglobulin in serum binds to polystyrene beads coated with two mouse monoclonal antibodies. These beads then react with a rabbit polyclonal antibody, biotinylated sheep anti-rabbit IgG, streptavidin-horseradish peroxidase, and a peroxidase substrate to yield a colored product that is measured spectrophotometrically at 492 nm. The range of the standard curve is 1...

متن کامل

Differences in radioimmunoassay results for thyroglobulin that affect management of patients with thyroid cancer.

We compared two commercial assays for measurement of serum thyroglobulin [Nuclear Medical Systems (NMS) and "CIS" (Damon Diagnostics)] with each other and with one developed at Stanford (J Clin Endocrinol Metab 49:557-564, 1979). The NMS assay is a competitive-binding RIA, the CIS and Stanford assays are two-site immunoradiometric assays. The kit standards varied in thyroglobulin concentration....

متن کامل

Performance Evaluation of the Serum Thyroglobulin Assays With Immunochemiluminometric Assay and Immunoradiometric Assay for Differentiated Thyroid Cancer

BACKGROUND Measurement of postoperative serum thyroglobulin (Tg) is important for detecting persistent or recurrent differentiated thyroid cancer. We evaluated the analytic performance of the DxI 800 assay (Beckman Coulter, USA) for serum Tg and anti-thyroglobulin antibodies (TgAbs) in comparison with that of the GAMMA-10 assay (Shinjin Medics Inc., Korea) for serum Tg and RIA-MAT 280 assay (St...

متن کامل

Comparison of an immunoradiometric and an immunoluminometric assay for the evaluation of the tumour associated antigens CA 19-9 and CA 125.

We evaluated the levels of CA 19-9 and CA 125 in the sera of healthy individuals, patients with non-neoplastic diseases known to produce elevated serum concentrations of CA 19-9 and CA 125, and patients with malignant tumours. The serum concentrations determined with an immunoradiometric assay (IRMA) and an immunoluminometric assay (ILMA) were compared. The accuracy was determined (as far as th...

متن کامل

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 48 7  شماره 

صفحات  -

تاریخ انتشار 2002