Propagation-based x-ray phase-contrast imaging with broad focus conventional x-ray sources

نویسندگان

  • M. G. Hönnicke
  • E. M. Kakuno
  • J. Manica
چکیده

A propagation-based x-ray phase-contrast imaging (PBI) setup using a conventional x-ray source (LFF Cu target) is presented. A virtual x-ray source of 40 x 50 μm was created by using, horizontally, a 6 take-off angle (with the x-ray tube working in the line focus geometry) and, vertically, a 50 μm slit . The sample was set 12 m from the source. Propagation-based x-ray phase-contrast (PB) image and conventional radiography (CR) of a polypropylene tube were acquired. Edge enhanced effects and a crack, not detected in CR, were clearly seen in the PB image. Contrast, visibility of the object edges and signal to noise ratio of the acquired images were exploited. The results show that PB images can be acquired by using normal focus (macro focus) conventional x-ray sources. This apparatus can be used as an standard phase-contrast imaging setup to analyze different kind of samples with large field of view (75 x 75 mm), discarding the use of translators for sample and detector.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources

X-ray radiographic absorption imaging is an invaluable tool in medical diagnostics and materials science. For biological tissue samples, polymers or fibre composites, however, the use of conventional X-ray radiography is limited due to their weak absorption. This is resolved at highly brilliant X-ray synchrotron or micro-focus sources by using phase-sensitive imaging methods to improve the cont...

متن کامل

X-Ray Phase Imaging for Medical Applications

X-ray radiographic absorption imaging is an invaluable tool in medical diagnostics and materials science. For biological tissue samples, polymers, or fiber composites, however, the use of conventional X-ray radiography is limited due to their weak absorption. This is resolved at highly brilliant X-ray synchrotron or micro-focus sources by using phase-sensitive imaging methods to improve contras...

متن کامل

Hard-X-ray dark-field imaging using a grating interferometer.

Imaging with visible light today uses numerous contrast mechanisms, including bright- and dark-field contrast, phase-contrast schemes and confocal and fluorescence-based methods. X-ray imaging, on the other hand, has only recently seen the development of an analogous variety of contrast modalities. Although X-ray phase-contrast imaging could successfully be implemented at a relatively early sta...

متن کامل

A coded-aperture technique allowing x-ray phase contrast imaging with conventional sources

Phase contrast imaging PCI solves the basic limitation of x-ray imaging, i.e., poor image contrast resulting from small absorption differences. Up to now, it has been mostly limited to synchrotron radiation facilities, due to the stringent requirements on the x-ray source and detectors, and only one technique was shown to provide PCI images with conventional sources but with limits in practical...

متن کامل

Phase and absorption retrieval using incoherent X-ray sources.

X-ray phase contrast imaging has overcome the limitations of X-ray absorption imaging in many fields. Particular effort has been directed towards developing phase retrieval methods: These reveal quantitative information about a sample, which is a requirement for performing X-ray phase tomography, allows material identification and better distinction between tissue types, etc. Phase retrieval se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008