Diagnostic analysis of RO desalting treated wastewater
نویسندگان
چکیده
Diagnostic analysis of reverse osmosis membranes that were fed with Western treatment plant (WTP) recycled water was investigated by both thermodynamic calculations and laboratory experiments in order to predict the feasibility of RO desalting for WTP. The thermodynamic calculations suggested that RO recoveries of 80–85% were feasible with careful control of feed water pH and the use of chemical additives such as antiscalants and chelating agents, it also predicted the major minerals of concern to be silica, calcium fluoride, calcium carbonate, and calcium phosphate. Following the thermodynamic simulations, diagnostic laboratory experiments were undertaken. The experiments showed that the major contributor to scale formation was indeed calcium phosphate and possibly another calcium based compound, which was strongly suspected to be calcium carbonate. Based on previously published literature that indicated anti-scalants did not substantially decrease the scaling effect of calcium phosphate and laboratory tests that indicated controlling the pH to 6.4 in the feed water dramatically reduced scaling formation, it was suggested that the feed water could be controlled by pH adjustments only. Inter-stage pH correction was suggested as an optional technique to enhance the overall water recovery to above 95%.
منابع مشابه
Reuse of Refinery Treated Wastewater in Cooling Towers
In this report, experimental investigation of waste water treatment by reverse osmosis to enable its reuse in cooling tower is presented. A polyamide spiral wound RO membrane followed by three filters as RO pretreatment (two activated carbon and one cartridge filter) and samples of Tehran refinery treated waste water have been used. The effect of operating conditions such as pressure differ...
متن کاملRemoving Fe, Zn and Mn from steel making plant wastewater using RO and NF membranes
Background and purpose: Excessive amount of heavy metals in industrial wastewater is a seriously crucial issue and requires efficient methods to be introduced and dealt with. Meanwhile, steel making plants as productive units in every country release large amounts of fluid into surface and underground sources. Typically, this wastewater contains heavy metals in minor amounts, while this amount ...
متن کاملDiagnostic characterization of gypsum scale formation and control in RO membrane desalination of brackish water
The utility of a laboratory diagnostic approach was investigated for a systematic evaluation of the impact of operating conditions, membrane type, and antiscalant effectiveness on membrane mineral salt scale formation. The study focused on low-pressure reverse osmosis (RO) membrane desalting of brackish water with high potential for scaling by calcium sulfate dihydrate (gypsum). Gypsum scale fo...
متن کاملExergetic, Exergoeconomic and Exergoenvironmental Multi-Objective Genetic Algorithm Optimization of Qeshm Power and Water Cogeneration Plant
In this study, optimization of Qeshm power and water desalting cogeneration plant has been investigated. The objective functions are related to maximizing exergetic efficiency and minimization of exergoeconomic and exergoenvironmental parameters. Also, the integration of RO desalination with the existing plant has been evaluated based on these analyses. This plant includes two MAPNA 25 MW gas t...
متن کاملReuse of Refinery Treated Wastewater in Cooling Towers
In this report, experimental investigation of waste water treatment by reverse osmosis to enable its reuse in cooling tower is presented. A polyamide spiral wound RO membrane followed by three filters as RO pretreatment (two activated carbon and one cartridge filter) and samples of Tehran refinery treated waste water have been used. The effect of operating conditions such as pressure difference...
متن کامل