Shear wave velocity measurements using acoustic radiation force impulse in young children with normal kidneys versus hydronephrotic kidneys

نویسندگان

  • Beomseok Sohn
  • Myung-Joon Kim
  • Sang Won Han
  • Young Jae Im
  • Mi-Jung Lee
چکیده

PURPOSE To measure shear wave velocities (SWVs) by acoustic radiation force impulse (ARFI) ultrasound elastography in normal kidneys and in hydronephrotic kidneys in young children and to compare SWVs between the hydronephrosis grades. METHODS This study was approved by an institutional review board, and informed consent was obtained from the parents of all the children included. Children under the age of 24 months were prospectively enrolled. Hydronephrosis grade was evaluated on ultrasonography, and three valid ARFI measurements were attempted using a high-frequency transducer for both kidneys. Hydronephrosis was graded from 0 to 4, and high-grade hydronephrosis was defined as grades 3 and 4. RESULTS Fifty-one children underwent ARFI measurements, and three valid measurements for both kidneys were obtained in 96% (49/51) of the patients. Nineteen children (38.8%) had no hydronephrosis. Twenty-three children (46.9%) had unilateral hydronephrosis, and seven children (14.3%) had bilateral hydronephrosis. Seven children had ureteropelvic junction obstruction (UPJO). Median SWVs in kidneys with high-grade hydronephrosis (2.02 m/sec) were higher than those in normal kidneys (1.75 m/sec; P=0.027). However, the presence of UPJO did not influence the median SWVs in hydronephrotic kidneys (P=0.362). CONCLUSION Obtaining ARFI measurements of the kidney is feasible in young children with median SWVs of 1.75 m/sec in normal kidneys. Median SWVs increased in high-grade hydronephrotic kidneys but were not different between hydronephrotic kidneys with and without UPJO.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acoustic radiation force impulse imaging of kidneys – a phantom study

AIM OF THE STUDY Since there have been only few works reporting the diagnosis of kidneys using Acoustic Radiation Force Impulse technique and those works do not provide consistent results of shear wave velocity measurements in renal tissue, we have decided to use kidney phantoms with known properties to examine the reliability of the method itself in a controlled setup similar to kidneys examin...

متن کامل

Acoustic radiation force impulse imaging with Virtual Touch™ tissue quantification: mean shear wave velocity of malignant and benign breast masses

Acoustic radiation force impulse imaging (ARFI) with Virtual Touch™ tissue quantification (VTTQ) enables the determination of shear wave velocity (SWV) in meters per second (m/s). The aim of our study was to describe the mean SWV in normal breast tissue and various breast masses. We performed measurements of SWV with ARFI VTTQ in 145 breast masses (57 malignant, 88 benign) and in the adjacent b...

متن کامل

Evaluation of Acoustic Radiation Force Impulse Imaging (ARFI) for the Determination of Liver Stiffness Using Transient Elastography as a Reference in Children.

PURPOSE Transient elastography (Fibroscan(©); (FS)) and acoustic radiation force impulse imaging (ARFI) represent noninvasive, user-friendly and quick methods providing an objective and reproducible measure of liver stiffness. The aim of the study was to evaluate cut-off values and performance of ARFI measurements in children using transient elastography as a reference. METHODS/PATIENTS A tot...

متن کامل

Acoustic Radiation Force Impulse Imaging for Non-Invasive Assessment of Renal Histopathology in Chronic Kidney Disease

OBJECTIVE To investigate the stiffness values obtained by acoustic radiation force impulse (ARFI) quantification in assessing renal histological fibrosis of chronic kidney disease (CKD). METHODS 163 patients with CKD and 32 healthy volunteers were enrolled between June 2013 and April 2014. ARFI quantification, given as shear wave velocity (SWV), was performed to measure renal parenchyma stiff...

متن کامل

Assessment of Placental Stiffness Using Acoustic Radiation Force Impulse Elastography in Pregnant Women with Fetal Anomalies

OBJECTIVE We aimed to evaluate placental stiffness measured by acoustic radiation force impulse (ARFI) elastography in pregnant women in the second trimester with a normal fetus versus those with structural anomalies and non-structural findings. MATERIALS AND METHODS Forty pregnant women carrying a fetus with structural anomalies diagnosed sonographically at 18-28 weeks of gestation comprised...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2014